Specifications

IP 240 Position Decoding
FB 25 LEN=67
F 12.4 = BACK ACTIV BACKWARD TRAVERSE PROGRAM ACTIVE
F 12.2 = FORW ACTIV FORWARD TRAVERSE PROGRAM ACTIVE
FW 14 = ANALOG VAL ANALOG VALUE TO BE OUTPUT IN UNITS (MAX. 1024)
Q 12.4 = HEATING HEATING ON (CONTACTOR + INDICATOR)
F 12.6 = FIN POINT FINAL POINT OF THE FORWARD TRAVERSE PROGRAM REACHED
F 12.3 = BACK START BACKWARD TRAVERSE PROGRAM STARTED
FY 2 = AUX BYTE1 SCRATCH FLAG BYTE CYCLIC PROGRAM
F 11.6 = PAFE TRAC8 FOR WRITING TRACK LIMITS (FB25)
F 12.7 = INT POINT INITIAL POINT/ORIGINAL POSITION REACHED
F 0.0 = ZERO SIGNAL FLAG ALWAYS RETAINS SIGNAL STATE ZERO
Q 12.1 = RUNNING RUN STARTED
Q 12.2 = ENABLED NEW RUN POSSIBLE
EWA 4NEB 811 6120-02a
7-51