Specifications
Position Decoding IP 240
OB 1 LEN=8
NETWORK 1 0000 CYCLE
0000 :JU FB 21
0001 NAME :IP PROG
0002 :BE
OB 2 LEN=16
NETWORK 1 0000 PROCESS INTERRUPT PROGRAM
0000 :JU FB 38 SAVE SCRATCH FLAGS
0001 NAME :FLAG.SAV
0002 DBNR : DB 38
0003 :
0004 :JU FB 27 INTERRUPT SERVICE ROUTINE FOR THE IP 240
0005 NAME :INTERPT
0006 :
0007 :JU FB 39 WRITE SCRATCH FLAGS
0008 NAME :LOAD.FLG
0009 DBNR : DB 38
000A :BE
FB 38 and FB 39 are not required in the S5-150U, S5-155U (150U mode) or S5-135U
(when set for interrupts at block boundaries).
OB 20 (in S5-115U: OB 21) LEN=9
NETWORK 1 0000 MANUAL RESTART
0000 :
0001 :JU FB 20 CONFIGURE THE IP 240 CHANNEL 1
0002 NAME :CONFIG
0003 :BE
OB 22 LEN=17
NETWORK 1 0000 RESTART AFTER POWER OFF
0000 :
0001 :JU FB 38 SAVE SCRATCH FLAGS (FY200-255)
0002 NAME :FLAG.SAV
0003 DBNR : DB 20
0004 :
0005 :JU FB 20 CONFIGURE THE IP 240 CHANNEL
0006 NAME :CONFIG
0007 :
0008 :JU FB 39 RELOAD SCRATCH FLAGS
0009 NAME :LOAD. FLG
000A DBNR : DB 20
000B :BE
FB 38 and FB 39 are not required in the S5-115U, S5-155U, or the S5-135U
when set for ”automatic restart on power-up” in DX0.
7-42
EWA 4NEB 811 6120-02a