Product manual

IP 266 STEP 5 Programming
START
FB 12 - NAME:LOAD
Program output
bytes 64 and 67 to 71
END
Mode 7 requires the following data:
Mode number in QB 64
Override factor in QB 67
Relative distance specification in bytes
QB 68 to QB 71
"Forward" or "Reverse" command in
QB 65
LKF+7
TQB64
L KF +100
TQB67
L KF +50
TQW68
LKF+0
TQW70
BE
These specifications define a distance of
50.000 mm.
Like the TOGGLE bit, the command is
alternately set and reset in FB 13.
EWA 4NEB 812 6057-02
9-35