Product manual
Fundamentals of COM 266 IP 266
"Type" column: O = output field
Field name
Tool ref. pt.:
Type
O
Description
The word "set" appears in this field when mode 5 has executed. The
word "reset" is displayed if there is no reference point.
CLC: O This field shows the controller status.
"On" is displayed in all modes except 3 and 4.
"Off" is displayed in modes 3 and 4.
Teach-Mode: O The word "on" is displayed in this field when a traversing (machining)
program is generated in mode 10. The word "off" appears only when
mode 10 is terminated with mode 11.
Status: O finished: No mode has been started.
As soon as the zero-speed monitor is tripped during a
traversing movement, the displayed changes from "running"
to "finished".
running: A mode has been started and is still in progress.
Mode
Program
Distance
Override
O In "actual-value display" mode, these fields are static output fields, and
are used to display the specified mode and all parameters.
6-60
EWA 4NEB 812 6057-02