Product manual
IP 266 Fundamentals of COM 266
6.6.1 "Actual-Value Display" Mode
Figure 6-23. "TEST" Form
SIMATIC S5/COM 266
T E S T DEVICE: IP 266 BLOCK: DB
Actual value : 12.105 [mm]
Following error : . 2 [mm]
Distance to go : . 0 [mm]
Aux. function : M02
Tool ref. pt. : reset CLC : on
Teach-Mode : off Status : finished
Mode : 4 FOLLOW-UP
Program :
Distance : [mm]
Override : (1% ... 200%)
F1
OP.MODE
F2
START
F3
STOP
F4 F5 F7 F8
EXIT
F6
In this "TEST" mode, the IP 266 provides the current actual position, following
error/speed, distance to go and switching functions.
These values are recomputed and redisplayed at regular intervals.
EWA 4NEB 812 6057-02
6-57