Smoke Alarm User Manual

Technical data
5.2 Technical data for IP-Module CVVA-IP
Electrical supply 12 V DC/24 V AC
Power requirement max. 6.0 W
Operating temperature range -10 – +50 °C, max. relative humidity 90%
Storage temperature range -20 – +60 °C, max. relative humidity 70%
Dimensions (H x Ø) 48 x 135 mm
Weight 620 g
Material Aluminum
IP rating IP66
System requirements All systems, which feature TCP/IP network functions and provide an
http browser (Microsoft Internet Explorer from version 5.5 with Java
plug-in or Mozilla or Netscape from version 7.0).
Protocols ARP, BOOTP/DHCP, TCP/IP, HTTP, ICMP, SNMP, FTP and DNS
Installation IP address configurable via ARP, BOOTP/DHCP, connection to twisted-
pair RJ45 Ethernet.
Network connection 10BaseT Ethernet or 100BaseTX Fast Ethernet, auto-sensing, full/half
duplex
Image formats QCIF (176x144),
CIF (352x288),
4CIF (704x576) (interlaced).
Image transmission Motion JPEG (multipart/x-mixed-replace content type), user
configurable JPEG single image frame quality, streaming up to 25
images per second with QCIF and CIF or up to 10 images per second
with 4CIF.
Security Separate passwords for image access and system configuration.
Hardware 8 MB RAM, 16 MB flash ROM
10
Siemens Building Technologies
Fire Safety & Security Products