Installation guide

Setup
84
Siemens Building Technologies
Fire Safety & Security Products 08.2007
SISTORE MX NVS supports the following network cameras:
Arecont Vision 2100, Vision 3130 Day, Vision 3130 Night
Axis 205, 206/W, 206M, 210, 211, 212 PTZ, 213 PTZ, 216FD, 221, 223M,
231D+, 232D+, 240Q, 241Q, 241S, Generic HTTP Interface V1.0,
Generic HTTP Interface V2.0
CBC MP2A, MP3DN Day, MP3DN Night
Digilan TV7214
Eneo ENC-1003L
IQ invision IQ501, IQ603, IQ 752
JVC VN-C10U; VN-C30U, VN-C625U, VN-C655U
Lumenera LE175C, LE275C, LE375C
Mobotix D12 one or two cameras, M1 Models, M10 Models, M10D-Night,
M12 Models, M12D-Night, M22M
Panasonic KX-HCM-280, WV-NM100/G, WV-NP244E, WV-NP472, WV-NS202,
WV-NS320, WV-NW470
Pixord 205
Samsung SNC-L200
Siemens CCIS1337-LP, CCIx1345, CFVA-IP NTSC, CFVA-IP PAL,
CVVA-IP NTSC, CVVA-IP PAL, TELSCAN WEB Server
Sony Generic HTTP interface, SNC-CS11, SNC-CS3P, SNC-DF40P,
SNC-M1/W, SNC-M3/W, SNC-P1, SNC-P5, SNC-RZ25P, SNC-RZ30P,
SNC-Z20P, SNT-V704
VINWP1 2051
Vivotek MJPEG Models, PZ6122, VS2402
Depending on the functional scope of the network camera, many operating
elements of the LAN cameras tab may be disabled.
Altogether a maximum of 32 network cameras can be connected.
Limitation: Network cameras cannot be connected to analogue video outputs.
Access to network cameras takes place with significantly greater latency. The
reason for this is the greater communication load between the SISTORE MX NVS
and a network camera.
Network cameras cause a significantly higher processor load of the SISTORE MX
NVS than analogue cameras. The frame rates required are the determining factor.
The operation of the system can be slow if all connections for network cameras
(32) are used.
NOTE:
To keep the processor load below 90 %, we recommend setting the resolution of network cameras
low (CIF format). The image quality should be set to approximately 70 %. The following rule applies:
The higher the performance of the server PC, the higher the image quality and the lower the
processor load. See Section. „System requirements“, page 56.
Exact specifications for the image quality and the required hard drive capacity are
not possible with network cameras, since each network camera has different
quality levels and interprets specifications differently.