s Installation Instructions for Intelli-Arc Diagnostic Tool Siemens Energy & Automation, Inc. Alpharetta, Georgia, U.S.A. P/N 811776 Rev 0P Intelli-ArcTM Diagnostic Tool Instruction Sheet Handheld device © 2009 Copyright Siemens Energy & Automation, Inc.
s Installation Instructions for Intelli-Arc Diagnostic Tool Siemens Energy & Automation, Inc. Alpharetta, Georgia, U.S.A. P/N 811776 Rev 0P DANGER Hazardous voltage. Will cause death or serious injury. This device necessitates working on or near equipment with exposed electrical hazards. Turn off and lock out power supplying equipment before connecting Arc Fault Diagnostic Tool. Ensure a safe work zone before re-energizing equipment for testing purposes. SAFETY INSTRUCTIONS 1.
s Installation Instructions for Intelli-Arc Diagnostic Tool Siemens Energy & Automation, Inc. Alpharetta, Georgia, U.S.A. P/N 811776 Rev 0P General TM The Intelli-Arc Diagnostic Tool is intended to analyze house hold circuits to localize arc faults. It can indicate early warnings of possible arcing before an AFCI breaker would trip. The Intelli-Arc Diagnostic Tool may show contributions from different loads that each individually would not create a trip condition.
s Installation Instructions for Intelli-Arc Diagnostic Tool Siemens Energy & Automation, Inc. Alpharetta, Georgia, U.S.A. P/N 811776 Rev 0P Set-Up Instructions See Figures 1 & 2 1. Turn “OFF” and lock out the power to the equipment in which the Arc Fault Diagnostic Tool is to be connected. 2. Move the handle of the breaker on the circuit to be analyzed to the “OFF” position. This circuit breaker serves as the disconnect device tor the Arc Fault Diagnostic Tool. 3.
s Installation Instructions for Intelli-Arc Diagnostic Tool Siemens Energy & Automation, Inc. Alpharetta, Georgia, U.S.A. P/N 811776 Rev 0P Operating Instructions 1. 2. 3. 4. De-energize all individual loads on the branch circuit under evaluation at the outlet (switch, receptacle, junction box, work box, etc.). While exercising caution, turn on the branch circuit breaker Turn “ON” the breaker supplying power to the branch circuit under evaluation. Turn “ON” the handheld device (Fig. 3).
s Siemens Energy & Automation, Inc. Alpharetta, Georgia, U.S.A. Installation Instructions for Intelli-Arc Diagnostic Tool P/N 811776 Rev 0P LED Indications Three sets of LED indicators are provided on the handheld device for use in troubleshooting branch circuit issues. These three indications give information regarding current (“AMPS”), ground fault level (“GF”), and arc fault level (“AF”). Current (“AMPS”) 1. The full scale current for this LED indication is 20+A. 2.
s Installation Instructions for Intelli-Arc Diagnostic Tool Siemens Energy & Automation, Inc. Alpharetta, Georgia, U.S.A.