Preparation - General information
– Before connecting the battery or switching the main power supply on, unplug the in-
ternal siren for the time of the installation (small plug with cable, directly on the left
lower side of the display).
– If the internal buzzer starts beeping: Press to silence it.
– To exit the system at any time: Press and hold the button
.
Reset back to factory setting:
– Reset all pins and numbers: Press 200 9 .
– Reset all individually changed parameters: Press 200 10 .
Language setting
1. Press
Ctrl
simultaneously
t the “Local Mode” opens.
2. Scroll with the buttons / to the posi-
tion “Language” and press to select.
3. Scroll with the buttons / to the lan-
guage you prefer and press to save.
4. To exit press and hold the button
.
Start programming
Programming the system (steps 2 -10) is
only possible in installer mode. To get into
installer mode the system must be disarmed!
1. Press user code “147258”
t the displays shows: “CLIENT:USER”.
2. Press installer code “258369”
t the displays shows: “ISTALLER:USERS”.
Clock setting
1. Set time: press 26 1 ”HHMM”
2. Set weekday: press 26 2 ”DAY”
(Sunday = 1, Monday = 2…etc.)
3. Set date: press
26 3 ”DDMMYY”
4. Activate automatic daylight saving (default
Europe GMT+1): press
26 4 1
Detectors
Learn the wireless detectors (max.16), be-
fore installing, to the panel. Default settings:
- Zones 1 and 2 are delayed for entry route.
- Zones 3 - 8 are set for normal zones.
- Zones 9 - 16 are set for Stay zones.
We recommend using:
- Zone 1: magnet contact from the entry
door.
- Zone 2: first motion detector for the surveil-
lance of the entry area (control panel).
1. For zone 1: press 164 1
t the keypad will start beeping to indicate
that learn mode has been activated.
2. Press the tamper contact on the detector
or remove the magnet from the door
contact
t it will send a transmission signal. The
panel will confirm if a detector is found
with the message “Found”.
3. Press to confirm.
4. Repeat actions 1 - 3 to follow up for the
zones 2 - 16 (use the navigation button
to switch to the next zone).
If a detector could not be learned it is either
already learned to the panel, or the transmis-
sion signal was not received - try again.
Already learned detectors can be checked in
“Find Detector” mode: press 166
Entry delay time
The entry delay time is set by default to 20
sec. To change the time (0-9999 seconds)
per zone:
1. Zone 1: press
144 1 ”seconds”
2. Zone 2: press
144 2 ”seconds”
Exit delay time
The exit delay time is set by default to 30
sec. To change the time (0 - 255 seconds)
per area:
Area A: press 60 1 ”seconds”
Remote control
Learn a remote control (max. 16) to the
system starting with user number 21 - 25.
Default setting:
User 21: ARM User 22: DISARM
User 23: STAY
User 25: FREE
User 24:
(
simultaneously ) PANIC/SOS
1. Remote control 1: press 18 21