Data Sheet for Product
4 / 6
Siemens Combined chip and transponder card encoders CE2N6353en_01
Building Technologies 2012-12-01
Engineering notes
The HXW3.2 access card encoder is a key element of the HOTEL SOLUTION
system. The number of HXW3.2 access card encoders must be in proper relation
to the hotel's size and thus be planned in sufficient numbers. The absolute mini-
mum number is 2 HXW3.2 access card encoders to ensure continued encoding
capability in case of HXW3.2 card encoder failure.
The card encoder should be located close to the Front Office System (FOS) or the
HOTEL SOLUTION operating workspace.
A null modem connection must be set up for HXW3.2 access card encoders locat-
ed at a distance to the PC containing the HOTEL SOLUTION database.
Mounting notes
• Use the devices only in closed, dry rooms
• Place horizontally on a flat surface
• Only trained staff may commission the device
• Do not open the device
• Observe all local safety and installation guidelines
Technical data
Operating voltage
Safety extra-low voltage SELV
DC 12 V ±15%
Power consumption
200 mA
Supply connection Plug on device rear Ext. dia. 5.5 mm , pin dia. 2 mm
Interface
Plugs on device rear
TCP/IP, RJ45, 8-pin
RS232, D-sub 9
Display LCD 2 lines at 16 characters each
Transponder card encoder Read/write chip Atmel/Temic T5567 or T5557
Working frequency 125 kHz
Transponder cards Antenna Rectangle, T5567
Working frequency 125 kHz
Reading distance <6 cm
Chip cards
Type
Siemens SLE5542 or SLE4442
Environmental conditions Operation
As per IEC 721-3-3: Class 3K5
Temperature
0...
+
50 °C
Humidity < 85% r.h.
Air pressure Min. 700 hPa, corresponds to max.
3,000 meters above mean sea level
Transport
As per IEC 721-3-2: Class 2K3
Temperature
−
25...
+
65 °C
Humidity < 95% r.h.
Air pressure Min. 260 hPa, corresponds to max.
10,000 meters above mean sea level
Standards
Product safety Automatic electrical controls for house-
hold and similar use
EN 60730
HXW3.2