3.9 Tools/test equipment
3.9.1 Installation, generation, and administration systems
No special tools are needed for the installation and start-up of the HiPath Xpressions Compact.
No separate inspection, measuring and test equipment is available for checking the HiPath Xpres-
sions Compact.
The HiPath Xpressions Compact board has 2 LEDs for local trouble-shooting.
They signal the following function states:
-
Description Green
LED
Yellow
LED
Boot procedure Off Off
LED test (cold-start option) On On
Reset of the Xpressions Compact
board and deletion of the CDB
Blinking Blinking
Display of the lockout switch status Off On: switch is in board locked
out position
Off: switch is in board enabled
position
Hard disk test and start of the
application
Off Blinking
Standby mode after successful
start-up
On Off
Board error or switch is in locked
out position
Off On
A switch can be used to block or release the board or to reset it. Existing connections are not
released because of the lock out, but a renewed seizure is prevented.
For more information, refer to Chapter 3.2 Start-up in the HiPath Xpressions Compact installation
and administration manual
3.9.2 Tools/test equipment
The tools and equipment for testing measuring and inspection are described in the Service Guide-
line General.