Operation Manual
Service Guideline HiPath Workpoint Clients
HiPath Xpressions Compact V1.0
Issue 1.0 from 02/02 Page 13 of 24
Installation
The HiPath Xpressions Compact boards are handled like other HiPath 3000 boards. HiPath
Xpressions Compact (P8/P8R and S8/S8R) boards may not be inserted or removed while the
system is running; the HiPath Xpressions Compact (L8) and (L24) boards may be removed while
the system is running.
Attention: packing protection covering:
Before starting up the board, the packing protection covering on the HiPath Xpressions Compact
board must be removed. When the board is returned or sent in (transport) for repair, this packing
protection covering (cardboard block) must be attached again.
System Requirements
The following requirements must be met for the installation of the HiPath Xpressions Compact:
• an available slot in HiPath 3700/3750 systems for one HiPath Xpressions Compact
(L24) not together with an SLMO24 on the same PCM bus, in
HiPath 3350/3550 wall systems only the lower slots
• one HiPath Xpressions
Compact board
per system: HiPath Xpressions Compact (P8): S30122-Q7379-X100
HiPath Xpressions Compact (P8R): S30122-Q7379-Z100
HiPath Xpressions Compact (S8): S30122-Q7379-X
HiPath Xpressions Compact (S8R): S30122-K7379-Z
HiPath Xpressions Compact (L8): S30122-Q7380-X100
HiPath Xpressions Compact (L24): S30122-Q7380-X
• a ferrite bead: only in HiPath 3700/3750 systems. Part number: C39022-Z7000-C7
HiPath Xpressions Compact software: HE100V.01.1xx and later (P50038-P0100-A1-*)
• PBX hardware: HiPath 3000 V1.2 with control unit (CBCPR, CBCC, CBCP, CBRC, CBRP)
• PBX software: HiPath 3700/3750: HE550S.53.7xx and later (P30370-P855-A610-*)
HiPath 3500/3550: HE550U.53.7xx and later (P30370-P856-A610-*)
HiPath 3300/3350: HE550T.53.7xx and later (P30370-P857-A610-*)
HiPath 3000 ManagerE: HA550B.53.xxx and later (P50038-P1510-A1-*)
Commissioning/start-up
Software and languages (voice prompts/system announcements) have already been installed on
the HiPath Xpressions Compact board. After the boards have been inserted, the start-up to
standby mode occurs (default start-up).
The proper system start-up can be monitored with the diagnostic LEDs.
Then the administration can be performed with the HiPath 3000 Manager E.
Customer Orientation:
The customer is given a brief introduction (basic training, 0.5 hour).