Network Router User Manual

128 GINA V4.0 System Administrator Guide – September 2000
Creating a configuration file using WinConfig
Start...
The Start menu item permits the customizing of the START and START_RM state-
ments.
A dialog window with five input fields is displayed when this menu item is activated:
Figure 18 Dialog window: Start system
The following table describes the dialog window entries; the “Statement” column specifies
the corresponding statement that is generated by WinConfig when saving to a configura-
tion file.
If a database vendor is defined in line 4 of the dialog box but line 5 is left blank, the appli-
cation name of the corresponding GINA application is the database name.
The buttons execute the following actions:
OK The entered parameter values are confirmed.
Delete All parameter values are deleted.
Cancel The modified parameter values are discarded again.
Parameter name Value Default Statement
Tasks Number of work processes none START
Asyntasks Number of asynchronous work pro-
cesses
none START
Tasks-in-Pgwt Number of tasks for PGWT tasks none START
DBVendor Name of the database vendor
Possible values:
Informix, Oracle, UDS or None
Selected via a pull-down menu
Infor-
mix
START_RM
DBName Name of the database none START_RM