Network Router User Manual
GINA V4.0 System Administrator Guide – September 2000 119
Creating a configuration file using WinConfi
g
Druck vom 24. 01.2001 17:00.44 torb-kon
The following table describes the dialog window entries; the “Statement” column specifies
the corresponding statement that is generated by WinConfig when saving to a configura-
tion file.
Parameter name Value Default Statement
Protocol Name of the protocol used LU6.1 FOREIGN_SESSION
Me -> Other Number of connections controlled
by the Me application
1 SESSION-POINT
Other -> Me Number of connections controlled
by the Other application
1 SESSION-POINT
AddressMe Specifies how the other foreign or
TA application is to be addressed
(see section 6.2 on page 46).
The two parameter values must be
separated by a dot.
none ADDRESS
AddressOther Specifies how the other foreign or
TA application is to be addressed
(see section 6.2 on page 46).
The two parameter values must be
separated by a dot.
none ADDRESS
In_Converter Function ID of the converter func-
tion or Class ID and ClassMethod
ID of the converter class method
(see section 6.2 on page 46 ).
When entering a Class ID and a
ClassMethod ID, they must be sep-
arated by a dot.
none IN_CONVERTER
Out_Converter Converter ID of the converter func-
tion (see section 6.2 on page 46).
If you enter 0, WinConfig does not
create an OUT_CONVERTER state-
ment.
0 OUT_CONVERTER
Map_System Enable/disable mapping
(see section
FOREIGN_SESSION
on page 54)
Possible values: yes / no
Selected via a toggle button