User Manual
4 / 8
Siemens A6V10636293_en--_b
Building Technologies 2018-04-09
Disposal
The device is considered electrical and electronic equipment for disposal in
terms of the applicable European Directive and may not be disposed of as
domestic garbage.
● Dispose of the device through channels provided for this purpose.
● Comply with all local and currently applicable laws and regulations..
Technical data
Power supply GDD161.1E/RW GDA161.1E/RW
Operating voltage DC 24…45 V ⎓ +25 % / -30 % (16.8…56.3 V ⎓)
1)
Power consumption Running 1.5 W 1.3 W
Holding 0.5 W 0.5 W
Functional data GDD161.1E/RW GDA161.1E/RW
Nominal torque
Maximum torque (blocked)
5 Nm
7 Nm
Nominal rotary angle
Max. rotary angle
90°
95° ± 2°
Runtime for 90° rotary angle 30 s 90 s
Actuator sound power level 32 dB(A) 30 dB(A)
Wiring connections (specific for railway vehicles)
Cable length 0.9 m
Cross-section 0.75 mm
2
Degree of protection
Insulation class III as per EN 60730
Housing protection IP 54 as per EN 60529
Environmental conditions
Temperature
Overtemperature (max.10 min / 15 °C)
Humidity
Condensation
-40...+70 °C
...+85 °C
<95 % r.F.
permitted
Standards, directives and approvals
Product standard
EN60730-2-14
Part 2-14 / Particular requirements for electric actuators
Railway applications EN 50155
Railway applications - Electronic equipment used on
rolling stock
EN 61373
Shock and vibration
EN 45545-2
Fire prevention in railway vehicles
Electromagnetic compatibility (Application area) For railway applications
Residential, commercial, light-industrial and industrial
environments
EU Conformity (CE)
GDD161.1E/RW
GDA161.1E/RW
A5W00026942
2)
A5W00026943
2)
RCM Conformity
GDD161.1E/RW
GDA161.1E/RW
A5W00026946
2)
A5W00026947
2)