User Manual

6-5
Siemens Switzerland Ltd www.siemens.com/gamma 2019
Building Technologies Division
Solar protection, anti-glare protection, utilization of daylight
Technical specications
Anti-glare/solar protection actuators
... Continuation of the table
Type
N522/03
N 523/02
N 523/03
N 523/04
2)
N 523/11
N 501
N 524
UP 520/03
UP 520/13
UP 520/31
RS 520/23
JB 520C23
RL 521/23
JB 521C23
Application program
1)
981101
980103
980183
981202
980602
981701
980202
982A01
982A01
207301
982A01
982A01
982B01
982B01
Output functions
Max. number of group addresses 114 100 100 110 200 220 40 120 120 26 120 120 120 120
Max. number of assignments 156 100 100 125 200 220 65 120 120 27 120 120 120 120
Configurable behavior in the event of a bus voltage
failure
n n n n n n n n n n
Configurable behavior in the event of a bus voltage
recovery
n n n n n n n n n
Configurable behavior in the event of a system
voltage recovery
n n n n
Operating mode
Automatic mode for sunlight tracking control n n n n n n n n n n n
Manual mode n n n n n n n n n n n
Standard mode n n n n n n n n n n n n n n
Status
Transmitting status per channel n n n n n n n n n n n n n
Indication of direct operation with status object n n n n
Status position of sun protection, 8-bit n n n n n n n n n n n n n
Status position of slats, 8-bit n n n n n n n n n n n n
Scene control
Integrated 1-bit scene control n n n n n n n n n n n
Integrated 8-bit scene control n n n n n n n n n
Scenes to be integrated per channel 8 2 2 8 8 8 8 8 8 8 8
Shutter/blind control
Travel lock
(e. g. for cleaning the outer shutter/blinds)
n n n n n n n n n n n n n
Separate raising/lowering protection n n n n n
Alarm
Move to safety position n n n n n n n n n n n n n n
Locking in this position for as long as alarm is
active
n n n n n n n n n n n n n n
Alarm check, wire break, alarm delayed n n n n n n n n n n n n n n
• Channels single lockable during alarm n n n n n n n n n n n n n n
Individual configuration of actuator channels n n n n n n n n n n n n n n
Shared configuration of actuator channels n n n n n n
Adaptation of objects and functions to drive type n n n n n n n n n n n n n
Delay time adjustable n n
Suitable for integration in a sunlight tracking
control system
n n n n n n n n n n n
End position detection n n n n n n n
Sun protection control (UP/DOWN)
Using position data (8-bit value) n n n n n n n n n n n
Travel to end position, stopping, stepwise adjust-
ment
n n n n n n n n n n n n n n
Slat control (OPEN/CLOSE)
Using position data (8-bit value) n n n n n n n n n n n
Travel to end position, stopping, stepwise adjust-
ment
n n n n n n n n n n n n n
Step adjustable
3)
% n n n % n n n n n n
1)
For current application programs, see www.siemens.com/gamma-td
2)
Also available as UL version, Product No.: 5WG1 523-1CB04
3)
n = number, % = %-value