Welding System User Manual

5. SYSTEM PARAMETERS English
Parameter Function Range
[Default]
Description / Notes
© Siemens plc 1997 G85139-H1750-U049-B
25
2
6/09/9
7
P041
Fixed frequency 1 (Hz) 0 - 400.00
[5.00]
Valid if P006 = 2 and P053 = 6 or 18.
P042
Fixed frequency 2 (Hz) 0 - 400.00
[10.00]
Valid if P006 = 2 and P052 = 6 or 18.
P043
Fixed frequency 3 (Hz) 0 - 400.00
[15.00]
Valid if P006 = 2 and P051 = 6 or 18.
P044
Fixed frequency 4 (Hz) 0 - 400.00
[20.00]
Valid if P006 = 2 and P051 = P052 = P053 = 17 .
P045
Inversion fixed setpoints for
fixed frequencies 1 - 4
0 - 7
[0]
Sets the direction of rotation for the fixed frequency:
FF 1 FF 2 FF 3 FF4
P045 = 0 ⇒⇒
P045 = 1 ⇐⇒
P045 = 2 ⇒⇐
P045 = 3 ⇒⇒
P045 = 4 ⇒⇒
P045 = 5 ⇐⇐
P045 = 6 ⇐⇐
P045 = 7 ⇐⇐
Fixed setpoints not inverted.
Fixed setpoints inverted.
P046
Fixed frequency 5 (Hz) 0 - 400.00
[25.00]
Valid if P006 = 2 and P051 = P052 = P053 = 17.
P047
Fixed frequency 6 (Hz) 0 - 400.00
[30.00]
Valid if P006 = 2 and P051 = P052 = P053 = 17.
P048
Fixed frequency 7(Hz) 0 - 400.00
[35.00]
Valid if P006 = 2 and P051 = P052 = P053 = 17.
P050
Inversion fixed setpoints for
fixed frequencies 5 - 7
0 - 7
[0]
Sets the direction of rotation for the fixed frequency:
FF 5 FF 6 FF 7
P050 = 0 ⇒⇒
P050 = 1 ⇐⇒
P050 = 2 ⇒⇐
P050 = 3 ⇒⇒
P050 = 4 ⇒⇒
P050 = 5 ⇐⇐
P050 = 6 or 7 ⇐⇐
Fixed setpoints not inverted.
Fixed setpoints inverted.