Operating Instructions

SINAMICS G120 CU230P-2 Control Units
List Manual, 04/2018, A5E33838102
371
2 Parameters
2.2 List of parameters
Dependency: Refer to: r3925
Note: The parameter is a copy of p1959.
Description: Configuration of voltage generation for the various MotID sections in the case of the most recent successful MotID.
Description: Displays the characteristics (A5E number and versions) of the power unit.
[0]: A5E number xxxx (A5Exxxxyyyy)
[1]: A5E number yyyy (A5Exxxxyyyy)
[2]: File version (logistic)
[3]: File version (fixed data)
[4]: File version (calib data)
r3929[0...n] Motor data identification modulated voltage generation / MotID U_gen mod
Access level: 4 Calculated: p0340 = 1 Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Wobble U_generate to determine dead-time
correction
Yes No -
01 Wobble U_generate to determine stator
resistance
Yes No -
02 Wobble U_generation to determine rotor
time constant
Yes No -
03 Wobble U_generation to determine leakage
inductance
Yes No -
04 Wobble U_generation to determine dynamic
leakage inductance
Yes No -
05 Wobble U_generation to determine
magnetizing inductance
Yes No -
08 Alternating U_generate to determine dead-
time correction
Yes No -
09 Alternating U_generate to determine stator
resistance
Yes No -
10 Alternating U_generate to determine rotor
time constant
Yes No -
11 Alternating U_generate to determine
leakage inductance
Yes No -
12 Alternating U_generate to determine dyn.
leakage inductance
Yes No -
13 Alternating U_generate to determine
magnetizing inductance
Yes No -
r3930[0...4] Power unit EEPROM characteristics / PU characteristics
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -