Operating Instructions

Table 10-64 PM240-2, PT, frame size F, 380 V … 480 V 3 AC
Article No. without filter
Article No. with filter
6SL3211-1PE32-5UL0
6SL3211-1PE32-5AL0
LO base load power 132 kW
LO base load input current 242 A
LO base load output current 250 A
HO base load power 110 kW
HO base load input current 218 A
HO base load output current 205 A
Fuse according to IEC
Fuse according to UL, class J
3NA3252 (315 A)
350 A
Power loss without filter 2.98 kW
1)
Power loss with filter 3.02 kW
1)
Required cooling air flow 153 l/s
Weight without filter 63.5 kg
Weight with filter 68 kg
1)
Approx. 2.6 kW through the heatsink
Table 10-65 PM240-2, frame size G, 380 V … 480 V 3 AC
Article No. with filter class C3
Article No. with filter class C2
6SL3210-1PE33-0CL0
6SL3210-1PE33-0AL0
6SL3210-1PE33-7CL0
6SL3210-1PE33-7AL0
6SL3210-1PE34-8CL0
6SL3210-1PE34-8AL0
LO base load power 160 kW 200 kW 250 kW
LO base load input current 300 A 365 A 470 A
LO base load output current 302 A 370 A 477 A
HO base load power 132 kW 160 kW 200 kW
HO base load input current 275 A 330 A 400 A
HO base load output current 250 A 302 A 370 A
Fuse according to IEC
Fuse according to UL, class J
Fuse according to IEC/UL
3NA3254 (355 A)
400 A
3NE1334-2 (500A)
3NA3260 (400 A)
500 A
3NE1334-2 (500A)
3NA3372 (630 A)
600 A
3NE1436-2 (630A)
Power loss with filter class C3
Power loss with filter class C2
3.67 kW
3.67 kW
4.62 kW
4.62 kW
6.18 kW
6.18 kW
Required cooling air flow 210 l/s 210 l/s 210 l/s
Weight with filter class C3
Weight with filter class C2
105 kg
107 kg
113 kg
114 kg
120 kg
120 kg
Technical data
10.6 Technical data, PM240-2 Power Module
Converter with the CU230P-2 Control Units
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257946B AF 501