Operating Instructions
SINAMICS G120 CU230P-2 Control Units
List Manual, 04/2018, A5E33838102
563
3 Function diagrams
3.3 Input/output terminals
Fig. 3-5 2201 – Connection overview
- 2201 -
Function diagram
87654321
fp_2201_97_01.vsd
Input/Output Terminals
G120 CU230P-2
13.03.2018 V4.7_10
Connection overview
Simulation for DI 0 ... DI 5
CU DI status
r0722
r0722
1
0
1
r0721
p0796
CU DI status inv
r0723
r0723
CU DI status
r0722
r0722
CU DI simulation
p0795
1 = Simulation on
T0
3 Digital outputs
[2221]
(52.7)
CU S_src DO 1
p0731
(52.3)
CU S_src DO 0
p0730
6 Digital inputs
[2242]
CU DI status inv
r0723
r0723
1
CU DI status
r0722
r0722
CU DI status inv
r0723
r0723
1
...
.0
.0
.5
.5
2 Analog outputs
(52.2)
CU S_src DO 2
p0732
[2261]
D
A
D
A
CU AO S_src
(27[0])
p0771
CU AO S_src
(21[0])
p0771
&
24 V
5 V
CU DI t_debounce
p0724
.0...12
.0...12
.0...12
.0...12
.0...12
[0]
[1]
...
2 Analog inputs[2251]
A
D
r0755
CU AI value in % [%]
1 Analog input[2252]
A
D
r0755
CU AI value in % [%]
LG-Ni1000
PT1000
Temperature evaluation (AI 3)[2270]
A
D
r0755
CU AI value in % [%]
LG-Ni1000
PT1000
[2]
[3]
[0]
CU DO inv
p0748
A
D
r0035
Mot temp [°C]
[2]
[8016] Thermal monitoring, motor
1
0
1
1
0
1
1
0
1
A
D
r0755
CU AI value in % [%]
[1]
X133
19
20
18
DO 0 NC
DO 0 NO
DO 0 COM
24
25
23
DO 2 NC
DO 2 NO
DO 2 COM
X134
22
21
DO 1 NO
DO 1 COM
X131
13
12
AO 0+
27
26
AO 1+
GND
X130
X131
8
7
6
5
DI 0
16
4
31
32
35
X130
17
50
36
10
11
AI 1+
AI 1-
GND
+10 V OUT
51
52
53
AI 2+
GND
AI 3+
GND
3
AI 0+
AI 0-
15
14
LG-Ni1000
PT1000
69
28
9
T1 MOTOR
T2 MOTOR
DI 1
DI 2
DI 3
DI 4
DI 5
DI COM
GND
+24 V OUT
GND
GND IN
+24 V IN