Data Sheet for Product
4
Siemens
N5111
2021-12-14
Technical design
Components
SINAMICS G120P is a combination of SINAMICS Control Unit CU230P-2 BT with the
SINAMICS Power Module PM230 that is harmonized and coordinated for pump and fan
applications, as well as an operator panel or a blanking cover. The operator panel or
blanking cover is not included in the scope of supply and must be separately ordered.
The following versions of CU230P-2 are available:
● CU230P-2 BT with RS485 interface for USS, Modbus RTU, BACnetMS/TP and P1. This
is included in the standard scope of supply of the G120P bundle.
● CU230P-2 CAN with CANopen interface. Optionally order.
● CU230P-2 DP with PROFIBUS DP interface. Optionally order.
● CU230P-2 PN with PROFINET IO interface. Optionally order.
The PM230 Power Module is available in the following versions:
● IP55 with integrated EMC filter A (C2) or integrated EMC filter B (C1)
● IP20 with integrated EMC filter A (C2) or unfiltered with external EMC filter B (C1)
● IP20 with integrated filter A or unfiltered in a push-through design (not available as
bundle, this must be ordered separately.)
Control Unit
CU230P-2 BT
CU230P-2 DP (PROFIBUS DP)
CU230P-2 CAN (CANopen)
Power Module
PM230
3 AC 380 ... 480 V
0 7 ... kW. 5 75 (IP20)
Operator panel
IOP-2-BT
Intelligent
Operator
Panel
or
BOP-2
Basic
Operator
Panel
or
Blanking
cover
Memory cards
Small mounting parts
Fan units
Optional accessory Spare parts
++
incl. shield connection kit
G120P Bundle order separately
0 7 ... 90 kW. 5 (IP55)
G_D011_ _00316EN b
A screening termination kit for the PM230 Power Module is included with the IP20 devices
in frame sizes A to C. For frame sizes D to F, the screening termination kit must be ordered
separately if required.
Options
Rear panels for mounting IP55, frame sizes FSA-FSC
To ensure the cooling capacity, IP55 devices in frame sizes FSA to FSC must be mounted
directly onto a flat wall. If this is not possible, for example in the case of a suspended
installation on a busbar system, an air guide sheet (available separately) must be attached.
This is cut to size and comes with the corresponding holes so it can be screwed directly onto
the rear of the Power Module.
You can find ordering information in the type summary.
Installation sets for IP55 devices
An appropriate installation set can be ordered for every frame size from FSA to FSF. This
allows you to ensure that all necessary installation material for correct cabling is available.
The sets comprise polyamide cable glands with separate rubber seals for a larger terminal
area for the power supply and control cables, as well as a high-quality EMC cable gland for
the motor cable, which enables the shield to be fed into the enclosure. This is required in
order to comply with the EMC C1 standard.