Installation Instructions

Screening plate fitting
1
2
2
Screening plate fitting
2
1
3
3
4
Air flow distances
AboveBelow
Ø 6 mm
mounting frame
fixing hole
FSC
e
e
aaa
aaa
d
c
b
mounting frame
fixing hole
mounting frame
fixing hole
mounting frame
fixing hole
Ø 6 mm
aa
aa
d
FSA/FSB
e
e
c
b
Height
Width
T1
T2
Depth
CU
IOP
Cutouts and drill patterns
in the cabinet wall for the
mounting frame
Push Through Units IP20 Units
Drill patterns and dimensions Drill patterns and dimensions
Dimensions IP20 Units FSA FSC
Frame
size
Dimensions (mm)
Distances
(mm)
1)
Fixings
Drill pattern
(mm)
Height
Width
Depth
Max.
d
epth
w
ith CU
Air flow
Screw
Tightening
Torque
(Nm)
a
b
c
With
Shielding
Plate
Above
Below
FSA
196
276
73
165
250
80
100
M4
2.5
186
62.3
6
FSB
292
370
100
165
250
80
100
M4
2.5
281
80
6
FSC
355
432
140
165
250
80
100
M5
3.5
343
120
6
1)
The Power Modules can be mounted
side
-
by
-
side. Due to tolerance reasons, we recommend a lateral
distance of about 1 mm
.
Dimensions PT Units
Frame
size
Dimensions (mm)
Distances
(mm)
1)
Fixings
Drill pattern and cutouts (mm)
Height
Width
Depth
Max.
d
epth
w
ith CU
and OP
Air flow
Screw
Tightening
Torque
(Nm)
a
b
c
d
e
With
Shielding
Plate
T1
T2
Above
Below
FSA
238
322
126
171
117.7
53.1
256
80
100
M5
3.5
103
106
88
198
27
FSB
345
430
154
171
117.7
53.1
256
80
100
M5
3.5
147.5
134
116
304
34.5
FSC
411
500
200
171
117.7
53.1
256
80
100
M5
3.5
123
174
156
365
30.5
1)
The Power Modules can be mounted side
-
by
-
side. Due to tolerance reasons, we recommend a lateral distance of about 1 mm
Cable length
Cable lengths
,
using
EMI Level
(Emission)
Screened cables, filtered units
(class A)
25
m
Second Environment, C2
1)
Screened cables, filtered units (class A)
50 m
Second Environment, C
3
1)
Screened cables, unfiltered units
with external filter, class B
50 m
C1
1)
Screened cables, unfiltered units
with external filter, class B
plus output choke
1
50 m
C2
1)
Screened cables, filtered or unfiltered units
5
0 m
EMI Standard not fullfilled
Unscreened cables, filtered or unfiltered units
100 m
EMI Standard not fullfilled
1)
EMC compliant connection requiered
36.5
a
c
b
FSA
a c
b
FSB / FSC
Height
Width
Depth
CU
IOP
Dimensions IP20 Units FSA FSC
Frame
size
Dimensions (mm)
Distances
(mm)
1)
Fixings
Drill pattern
(mm)
Height
Width
Depth
Max.
d
epth
w
ith CU
and OP
Air flow
Screw
Tightening
Torque
(Nm)
a
b
c
With
Shielding
Plate
Above
Below
FSA
196
276
73
165
250
80
100
M4
2.5
186
62.3
6
FSB
292
370
100
165
250
80
100
M4
2.5
281
80
6
FSC
355
432
140
165
250
80
100
M5
3.5
343
120
6
1)
The Power Modules can be mounted
side
-
by
-
side. Due to tolerance reasons, we recommend a lateral
distance of about 1 mm
.
Dimensions PT Units
Frame
size
Dimensions (mm)
Distances
(mm)
1)
Fixings
Drill patte
Height
Width
Depth
Max.
d
epth
w
ith CU
and OP
Air flow
Screw
Tightening
Torque
(Nm)
a
With
Shielding
Plate
T1
T2
Above
Below
FSA
238
322
126
171
117.7
53.1
256
80
100
M5
3.5
103
106
FSB
345
430
154
171
117.7
53.1
256
80
100
M5
3.5
147.5
134
FSC
411
500
200
171
117.7
53.1
256
80
100
M5
3.5
123
174
1)
The Power Modules can be mounted side
-
by
-
side. Due to tolerance reasons, we recommend a lateral distance of about 1 mm
Cable length
Cable lengths
,
using
EMI Level
(Emission
Screened cables, filtered units
(class A)
25
m
Second Environment, C2
Screened cables, filtered units (class A)
50 m
Second Environment, C
Cabinet
Seal
Mounting Frame
It is recommended that the optional mounting frame is used
to install the Push-through Power Module in a cabinet. This
optional mounting frame is designed in conjunction with the
supplied seal to easily maintain an IP55 rating of the
enclosure (the seal is delivered with the Power Module). If the
Power Module is mounted without using the optional
Mounting frame, it is the user’s responsibility to ensure the
correct IP protection rating is reached.
FSA: 6SL3260-6AA00-0DA0
FSB: 6SL3260-6AB00-0DA0
FSC: 6SL3260-6AC00-0DA0
Getting Started
SINAMICS G120
Power Module PM230 FSA ... FSC
*A5E33582380A-AA*
接触带电部件会引发生命危险
本设备会传导危险电压。
接触带电部件可能会造成人员重伤,甚至是死亡。
本设备的运行应根据所配备的安装/操作手册中的详细安装和操作说明进行。
警告
Pericolo di morte per contatto con parti sotto tensione
In questo apparecchio sono presenti tensioni pericolose.
Il contatto con parti sotto tensione può provocare la morte o gravi lesioni.
L’utilizzo di questo apparecchio richiede istruzioni dettagliate per l’installazione e
l’esercizio, che sono riportate nel manuale di installazione e d’uso di questo prodotto.
Avvertenza
Peligro de muerte al tocar piezas bajo tensión
En el presente equipo hay aplicadas tensiones peligrosas.
Tocar piezas que están bajo tensión puede provocar lesiones corporales graves o
incluso la muerte.
El funcionamiento de este equipo requiere unas instrucciones de instalación y servicio
detalladas como las que figuran en el manual de montaje o las instrucciones de
servicio del mismo.
Advertencia
Danger de mort en cas de contact avec des pièces sous tension
L'appareil présente des tensions électriques dangereuses.
Tout contact avec des parties sous tension peut entraîner la mort ou des blessures
graves.
La mise en œuvre de cet appareil nécessite les instructions détaillées d'installation et
de service fournies dans le manuel d'installation/de service correspondant au produit.
Attention
Danger to life when live parts are touched
The present device conducts hazardous voltages.
Touching live components can result in death or severe injury.
Operation of this equipment requires detailed installation and operation instructions
provided in the installation/operation manual intended for use with this product.
Warning
Lebensgefahr durch Berührung unter Spannung stehender Teile
Das vorliegende Gerät führt gefährliche Spannungen.
Beim Berühren unter Spannung stehender Teile erleiden Sie Tod oder schwere
Körperverletzungen.
Der Betrieb dieses Gerätes erfordert detaillierte Installations- und Betriebsanwei-
sungen, wie sie im Montagehandbuch / der Betriebsanleitung für dieses Gerät
enthalten sind.
Warnung
Declaration of Conformity
The Declaration of Conformity can be found at the following link:
http://support.automation.siemens.com/WW/view/en/30563514/134200
Siemens AG,
Frauenauracher Str. 80,
DE-91056 Erlangen
Issue 04/2014
Scan the QR code to
obtain further
information on
SINAMICS G120.

Summary of content (2 pages)