Operating Instructions
SINAMICS G120 CU230P-2 Control Units
List Manual (LH9), 04/2014, A5E33838102B AA
559
3 Function diagrams
3.8 Internal control/status words
Fig. 3-54 2534 – Status word, monitoring functions 1
- 2534 -
Function diagram
87654321
fp_2534_97_01.vsd
Internal control/status words
G120 CU230P-2
07.04.2014 V4.7
Status word, monitoring functions 1
9
10
8
7
6
5
4
3
2
1
0
<1>
1
ZSW monitor 1
r2197
r2197
From speed signals
From speed signals
From speed signals
From speed signals
Status word, monitoring functions 1 (r2197)
Bit No.
1 = |n_act| <= n_min p1080
1 = |n_act| >= n_set
1 = |n_act| <= n_standstill p1226
1 = I_act >= I_threshold p2170
1 = Vdc_act <= Vdc_threshold p2172
1 = Vdc_act > Vdc_threshold p2172
1 = |n_act| <= speed threshold value 2 (p2155)
1 = |n_act| > speed threshold value 2 (p2155)
1 = n_act >= 0
1 = |n_act| > n_max
1 = Speed setpoint - actual value deviation within tolerance t_off
n_act = smoothed speed actual value r2169 [8010.2].
11
12
1 = Load missing
From extended signals
From extended signals
From extended signals
From extended signals
From extended signals
From extended signals
From extended signals
13
14
15
Reserved
Reserved
r2197.0
r2197.1
r2197.4
r2197.5
r2197.11
r2197.2
r2197.6
r2197.9
r2197.3
r2197.7
r2197.8
r2197.10
[8020.8]
[8010.8]
[8011.8]
[8020.8]
[8020.8]
[8010.8]
[8011.8]
[8020.8]
[8020.8]
[8020.8]
[8020.8]
1 = |n_act| > n_max
Reserved
(F07901)
<1>
<1>
r2197.13