Dimension drawing PM230 Power Module, IP20
H
B
T1
T2
Power Module PM230, IP20 with integrated line filter A
Dimensions (mm) Clearances (mm)
2)
Frame size H
1)
B T1 with
IOP-2-BT
T1 with
blanking
cover/
BOP-2
T2 without
cover
Waste heat
(top)
Cooling air
(bottom)
FSA 196 73 245 235 223 80 100
FSB 292 100 245 235 223 80 100
FSC 355 140 245 235 223 80 100
FSD 512 275 275 265 253 300 300
FSE 635 275 275 265 253 300 300
FSF 934 350 387 377 365 350 350
Power Module PM230, IP20 with external filter B
Dimensions (mm) Clearances (mm)
2)
Frame size H
1)
B T1 with
IOP-2-BT
T1 with
blanking
cover/
BOP-2
T2 without
cover
Waste heat
(top)
Cooling air
(bottom)
FSA 202 73 310 300 288 80 100
FSB 297 100 330 320 308 80 100
FSC 359 140 340 330 318 80 100
FSD 512 375 275 265 253 300 300
FSE 635 385 275 265 253 300 300
FSF 934 500 387 377 365 350 350