Operating Instructions
2 Parameters
2.4 BICO parameters (connectors/binectors)
SINAMICS G120 CU230P-2 Control Units
540 List Manual, 04/2018, A5E33838102
2.4.4 Connector outputs (CO)
Product: SINAMICS G120, Version: 4711200, Language: eng, Type: CO
r0021 CO: Actual speed smoothed / Actual speed
r0025 CO: Output voltage smoothed / Output voltage
r0026 CO: DC link voltage smoothed / DC link voltage
r0027 CO: Absolute actual current smoothed / Motor current
r0032 CO: Active power actual value smoothed / Power
r0034 CO: Motor utilization thermal / Mot_util therm
r0035 CO: Motor temperature / Mot temp
r0036 CO: Power unit overload I2t / PM overload I2t
r0037[0...19] CO: Power unit temperatures / PM temperatures
r0039[0...2] CO: Energy display / Energy display
r0042[0...2] CO: Process energy display / Proc energy disp
r0060 CO: Speed setpoint before the setpoint filter / n_set before filt.
r0062 CO: Speed setpoint after the filter / n_set after filter
r0063[0...2] CO: Actual speed / Actual speed
r0064 CO: Speed controller system deviation / n_ctrl sys dev
r0066 CO: Output frequency / f_outp
r0067 CO: Output current maximum / Current max
r0068[0...1] CO: Absolute current actual value / I_act abs val
r0069[0...8] CO: Phase current actual value / I_phase act val
r0070 CO: Actual DC link voltage / Vdc act val
r0072 CO: Output voltage / U_output
r0074 CO: Modulat_depth / Mod_depth
r0075 CO: Current setpoint field-generating / Id_set
r0076 CO: Current actual value field-generating / Id_act
r0077 CO: Current setpoint torque-generating / Iq_set
r0078 CO: Current actual value torque-generating / Iq_act
r0079 CO: Torque setpoint / M_set
r0080[0...1] CO: Torque actual value / Actual torque
r0082[0...2] CO: Active power actual value / P_act
r0083 CO: Flux setpoint / Flex setp
r0084[0...1] CO: Flux actual value / Actual flux
r0087 CO: Actual power factor / Cos phi act
r0289 CO: Maximum power unit output current / PU I_outp max
r0752[0...3] CO: CU analog inputs input voltage/current actual / CU AI U/I_inp act
r0755[0...3] CO: CU analog inputs actual value in percent / CU AI value in %
p0791[0...1] CO: Fieldbus analog outputs / Fieldbus AO
r0944 CO: Counter for fault buffer changes / Fault buff change
p1001[0...n] CO: Fixed speed setpoint 1 / n_set_fixed 1
p1002[0...n] CO: Fixed speed setpoint 2 / n_set_fixed 2
p1003[0...n] CO: Fixed speed setpoint 3 / n_set_fixed 3
p1004[0...n] CO: Fixed speed setpoint 4 / n_set_fixed 4
p1005[0...n] CO: Fixed speed setpoint 5 / n_set_fixed 5
p1006[0...n] CO: Fixed speed setpoint 6 / n_set_fixed 6
p1007[0...n] CO: Fixed speed setpoint 7 / n_set_fixed 7
p1008[0...n] CO: Fixed speed setpoint 8 / n_set_fixed 8
p1009[0...n] CO: Fixed speed setpoint 9 / n_set_fixed 9
p1010[0...n] CO: Fixed speed setpoint 10 / n_set_fixed 10
p1011[0...n] CO: Fixed speed setpoint 11 / n_set_fixed 11
p1012[0...n] CO: Fixed speed setpoint 12 / n_set_fixed 12
p1013[0...n] CO: Fixed speed setpoint 13 / n_set_fixed 13
p1014[0...n] CO: Fixed speed setpoint 14 / n_set_fixed 14
p1015[0...n] CO: Fixed speed setpoint 15 / n_set_fixed 15
r1024 CO: Fixed speed setpoint effective / Speed fixed setp