Installation Instructions

Table Of Contents
7.4 Ambient conditions
Property Version
Ambient conditions for transport in the transport packaging
Climatic ambient conditions ‑ 40 °C … + 70 °C, according to Class 2K4 to EN 60721‑3‑2
maximum humidity 95 % at 40 °C
Mechanical ambient condi‐
tions
FSA … FSC: Shock and vibration permissible according to 1M2 to EN 60721‑3‑2
FSD … FSF: Shock and vibration permissible according to 2M3 to EN 60721‑3‑2
Protection against chemical
substances
Protected according to Class 2C2 to EN 60721‑3‑2
Biological environmental
conditions
Suitable according to Class 2B1 to EN 60721‑3‑2
Ambient conditions for long-term storage in the product packaging
Climatic ambient conditions ‑ 25 °C … + 55 °C, according to Class 1K3 to EN 60721‑3‑1
Protection against chemical
substances
Protected according to Class 1C2 to EN 60721‑3‑1
Biological environmental
conditions
Suitable according to Class 1B1 according to EN 60721‑3‑1
Ambient conditions in operation
Installation altitude Up to 1000 m above sea level without derating,
> 1000 m Restrictions for special ambient conditions (Page 69)
Climatic ambient conditions
1)
Temperature range without derating
2)
LO base load power: 0 °C...40 °C
HO base load power: 0 °C...40 °C
For higher temperatures.
Restrictions for special ambient conditions (Page 69)
Relative humidity: 5 … 95%, condensation not permitted
Oil mist, salt mist, ice formation, condensation, dripping water, spraying water, splashing
water and water jets are not permitted
Mechanical ambient condi‐
tions
FSA … FSF: Vibration levels permissible according to Class 3M1 to EN 60721-3-3
FSA … FSC: Shock, permissible according to Class 3M2 to EN 60721-3-3
FSD … FSF: Shock permissible according to Class 3M1 to EN 60721-3-3
Protection against chemical
substances
protected according to 3C2 acc. to EN 60721‑3‑3
Biological environmental
conditions
suitable according to 3B1 acc. to EN 60721‑3‑3
Pollution Suitable for environments with degree of pollution 2 according to EN 61800-5-1
Cooling Forced air cooling AF, according to EN 60146
Cooling air clean and dry air
1)
Increased ruggedness regarding temperature range and relative humidity; therefore better than Class 3K3 to EN 60721-3-3
2)
Observe the permissible ambient temperatures for the Control Unit and possibly the operator panel (IOP or BOP-2).
Technical specifications
7.4 Ambient conditions
Power Module PM230, IP20 / Push-through technology (PT)
62 Hardware Installation Manual, 08/2016, A5E34331322B AB