Operating Instructions
2 Parameters
2.4 BICO parameters (connectors/binectors)
SINAMICS G120 CU230P-2 Control Units
542 List Manual, 04/2018, A5E33838102
p2201[0...n] CO: Technology controller fixed value 1 / Tec_ctrl fix val1
p2202[0...n] CO: Technology controller fixed value 2 / Tec_ctr fix val 2
p2203[0...n] CO: Technology controller fixed value 3 / Tec_ctr fix val 3
p2204[0...n] CO: Technology controller fixed value 4 / Tec_ctr fix val 4
p2205[0...n] CO: Technology controller fixed value 5 / Tec_ctr fix val 5
p2206[0...n] CO: Technology controller fixed value 6 / Tec_ctr fix val 6
p2207[0...n] CO: Technology controller fixed value 7 / Tec_ctr fix val 7
p2208[0...n] CO: Technology controller fixed value 8 / Tec_ctr fix val 8
p2209[0...n] CO: Technology controller fixed value 9 / Tec_ctr fix val 9
p2210[0...n] CO: Technology controller fixed value 10 / Tec_ctr fix val 10
p2211[0...n] CO: Technology controller fixed value 11 / Tec_ctr fix val 11
p2212[0...n] CO: Technology controller fixed value 12 / Tec_ctr fix val 12
p2213[0...n] CO: Technology controller fixed value 13 / Tec_ctr fix val 13
p2214[0...n] CO: Technology controller fixed value 14 / Tec_ctr fix val 14
p2215[0...n] CO: Technology controller fixed value 15 / Tec_ctr fix val 15
r2224 CO: Technology controller fixed value effective / Tec_ctr FixVal eff
r2245 CO: Technology controller mot. potentiometer setpoint before RFG / Tec_ctr mop befRFG
r2250 CO: Technology controller motorized potentiometer setpoint after RFG / Tec_ctr mop aftRFG
r2260 CO: Technology controller setpoint after ramp-function generator / Tec_ctr set aftRFG
r2262 CO: Technology controller setpoint after filter / Tec_ctr set aftFlt
r2266 CO: Technology controller actual value after filter / Tec_ctr act aftFlt
r2272 CO: Technology controller actual value scaled / Tech_ctrl act scal
r2273 CO: Technology controller system deviation / Tec_ctrl sys_dev
p2291 CO: Technology controller maximum limiting / Tec_ctrl max_lim
p2292 CO: Technology controller minimum limiting / Tec_ctrl min_lim
r2294 CO: Technology controller output signal / Tec_ctrl outp_sig
p2295 CO: Technology controller output scaling / Tec_ctrl outp scal
r2316 CO: Technology controller, Kp adaptation output / Kp adapt outp
r2322 CO: Technology controller Tn adaptation output / Tn adapt output
r2344 CO: Technology controller last speed setpoint (smoothed) / Tec_ctrl n_setp_sm
r2397[0...1] CO: Hibernation mode output speed actual / Hib n_outp act
p2900[0...n] CO: Fixed value 1 [%] / Fixed value 1 [%]
p2901[0...n] CO: Fixed value 2 [%] / Fixed value 2 [%]
r2902[0...14] CO: Fixed values [%] / Fixed values [%]
p2930[0...n] CO: Fixed value M [Nm] / Fixed value M [Nm]
r3131 CO: Actual fault value / Act fault val
r3132 CO: Actual component number / Comp_no act
r8541 CO: Speed setpoint from the IOP in the manual mode / n_set IOP
r8745[0...15] CO: CAN free PZD receive objects 16 bit / Free PZD recv 16
r8747[0...7] CO: CAN free PZD receive objects 32 bit / Free PZD recv 32
r8762 CO: CAN operating mode display / Op mode display
r8784 CO: CAN status word / Status word
r8792[0] CO: CAN velocity mode I16 setpoint / Vel mod I16 set
r8796[0] CO: CAN profile velocity mode I32 setpoints / Pr vel mo I32 set
r8797[0] CO: CAN profile torque mode I16 setpoints / Pr Tq mod I16 set
r11060 CO: Free tec_ctrl 0 setpoint after ramp-function generator / Ftec0 setp aft RFG
r11072 CO: Free tec_ctrl 0 actual value after limiter / Ftec0 act v af lim
r11073 CO: Free tec_ctrl 0 system deviation / Ftec0 sys dev
p11091 CO: Free tec_ctrl 0 limit maximum / Ftec0 lim max
p11092 CO: Free tec_ctrl 0 limit minimum / Ftec0 lim min
r11094 CO: Free tec_ctrl 0 output signal / Ftec0 out_sig
r11160 CO: Free tec_ctrl 1 setpoint after ramp-function generator / Ftec1 setp aft RFG
r11172 CO: Free tec_ctrl 1 actual value after limiter / Ftec1 act v af lim
r11173 CO: Free tec_ctrl 1 system deviation / Ftec1 sys dev
p11191 CO: Free tec_ctrl 1 limit maximum / Ftec1 lim max