Operating Instructions

2 Parameters
2.3 Parameters for data sets
SINAMICS G120 CU230P-2 Control Units
530 List Manual, 04/2018, A5E33838102
p2211[0...n] CO: Technology controller fixed value 11 / Tec_ctr fix val 11
p2212[0...n] CO: Technology controller fixed value 12 / Tec_ctr fix val 12
p2213[0...n] CO: Technology controller fixed value 13 / Tec_ctr fix val 13
p2214[0...n] CO: Technology controller fixed value 14 / Tec_ctr fix val 14
p2215[0...n] CO: Technology controller fixed value 15 / Tec_ctr fix val 15
p2216[0...n] Technology controller fixed value selection method / Tec_ctr FixVal sel
p2230[0...n] Technology controller motorized potentiometer configuration / Tec_ctr mop config
p2237[0...n] Technology controller motorized potentiometer maximum value / Tec_ctrl mop max
p2238[0...n] Technology controller motorized potentiometer minimum value / Tec_ctrl mop min
p2240[0...n] Technology controller motorized potentiometer starting value / Tec_ctrl mop start
p2247[0...n] Technology controller motorized potentiometer ramp-up time / Tec_ctr mop t_r-up
p2248[0...n] Technology controller motorized potentiometer ramp-down time / Tec_ctrMop t_rdown
p2370[0...n] Closed-loop cascade control enable / Csc_ctrl enab
p2390[0...n] Speed start of hibernation mode / Hib mode n_start
p2391[0...n] Hibernation mode delay time / Hib mode t_delay
p2393[0...n] Hibernation mode restart speed relative w/o techn controller / Hib start w/o tec
p2394[0...n] Hibernation mode boost time period / Hib mode t_boost
p2395[0...n] Hibernation mode boost speed / Hib mode n_boost
p2396[0...n] Hibernation mode max. shutdown time / Hib t_off max
p2900[0...n] CO: Fixed value 1 [%] / Fixed value 1 [%]
p2901[0...n] CO: Fixed value 2 [%] / Fixed value 2 [%]
p2930[0...n] CO: Fixed value M [Nm] / Fixed value M [Nm]
p3231[0...n] Load monitoring speed deviation / Load monit n_dev
p3233[0...n] Torque actual value filter time constant / M_act_filt T
p3315[0...n] Efficiency optimization 2 minimum flux limit value / Min flux lim val
p3316[0...n] Efficiency optimization 2 maximum flux limit value / Max flux lim val
p3320[0...n] Fluid flow machine power point 1 / Fluid_mach P1
p3321[0...n] Fluid flow machine speed point 1 / Fluid_mach n1
p3322[0...n] Fluid flow machine power point 2 / Fluid_mach P2
p3323[0...n] Fluid flow machine speed point 2 / Fluid_mach n2
p3324[0...n] Fluid flow machine power point 3 / Fluid_mach P3
p3325[0...n] Fluid flow machine speed point 3 / Fluid_mach n3
p3326[0...n] Fluid flow machine power point 4 / Fluid_mach P4
p3327[0...n] Fluid flow machine speed point 4 / Fluid_mach n4
p3328[0...n] Fluid flow machine power point 5 / Fluid_mach P5
p3329[0...n] Fluid flow machine speed point 5 / Fluid_mach n5
p3855[0...n] DC quantity controller configuration / Rect_ctrl config
p3856[0...n] Compound braking current / Compound I_brake
p3857[0...n] DC quantity controller P gain / DC_ctrl Kp
p3858[0...n] DC quantity controller integral time / DC_ctrl Tn
r3925[0...n] Identification final display / Ident final_disp
r3927[0...n] Motor data identification control word / MotID STW
r3928[0...n] Rotating measurement configuration / Rot meas config
r3929[0...n] Motor data identification modulated voltage generation / MotID U_gen mod