Operating Instructions

Manually backing up
Preconditions
The inverter power supply has been switched on.
No memory card is inserted in the inverter.
Procedure with Startdrive
1. Go online.
2. Select "Online & diagnostics".
3. Select "Backing up/reset".
4. Back up the settings to the EEPROM of the inverter.
5. Select the settings as shown in the diagram.
6. Start data transfer
7. Wait until Startdrive reports that data backup has been completed.
You have backed up the inverter settings to a memory card.
Procedure with the BOP-2
1. Remove any USB cable that is inserted in the inverter.
(;75$6
72&$5'
2. In the "OPTIONS" menu, select "TO CARD".
Saving the settings and series commissioning
7.1 Backing up and transferring settings using a memory card
Converter with the CU230P-2 Control Units
382 Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257946B AF