Operating Instructions

SINAMICS G120 CU230P-2 Control Units
List Manual, 04/2018, A5E33838102
41
2 Parameters
2.2 List of parameters
Note: CDS: Command Data Set
DDS: Drive Data Set
The following control bits are displayed in r0055:
Bit 00: r1198.0
Bit 01: r1198.1
Bit 02: r1198.2
Bit 03: r1198.3
Bit 04: r0837.0
Bit 05: r0837.1
Bit 08: r2349.0 (negated)
Bit 09: r1239.11
Bit 13: r2138.13 (negated)
Bit 15: r0836.1
Description: Display and BICO output for the status word of the closed-loop control.
Description: Display and BICO output for the status word of the closed-loop control.
09 DC braking enable Yes No -
11 Reserved - - -
12 Reserved - - -
13 External fault 1 (F07860) No Yes -
15 CDS bit 1 Yes No -
r0056.0...15 CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
PM230
PM240, PM330
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2526
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Initialization completed Yes No -
01 De-magnetizing completed Yes No -
02 Pulse enable available Yes No -
04 Magnetizing completed Yes No -
05 Voltage boost when starting Active Inactive 6301
06 Acceleration voltage Active Inactive 6301
07 Frequency negative Yes No -
08 Field weakening active Yes No -
09 Voltage limit active Yes No 6714
10 Slip limit active Yes No 6310
11 Frequency limit active Yes No -
12 Current limiting controller voltage output
active
Yes No -
13 Current/torque limiting Active Inactive 6060
14 Vdc_max controller active Yes No 6220,
6320
15 Vdc_min controller active Yes No 6220,
6320
r0056.0...13 CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
PM250
PM260
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2526
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Initialization completed Yes No -
01 De-magnetizing completed Yes No -
02 Pulse enable available Yes No -
04 Magnetizing completed Yes No -