Operating Instructions
Parameters
Overview of parameters
1-12
© Siemens AG 2008 - 2013 All Rights Reserved
SINAMICS G120 CU230P-2 Control Units List Manual (LH9), 01/2013
Calculated
Specifies whether the parameter is influenced by automatic calculations.
p0340 determines which calculations are to be performed:
• p0340 = 1 includes the calculations from p0340 = 2, 3, 4, 5.
• p0340 = 2 calculates the motor parameters (p0350 ... p0360, p0625).
• p0340 = 3 includes the calculations from p0340 = 4, 5.
• p0340 = 4 only calculates the controller parameters.
• p0340 = 5 only calculates the controller limits.
Parameters with a reference to p0340 after "Calculated", depend on the Power
Module being used and the motor. In this case, the values at "Factory setting" do
not correspond to the actual values because these values are calculated during
the commissioning. This also applies to the motor parameters.
Data type
The information on the data type can consist of the following two items (separated
by a slash):
• First item
Data type of the parameter.
• Second item (for binector or connector input only)
Data type of the signal source to be interconnected (binector/connector out-
put).
Parameters can have the following data types:
Note:
For p3900 > 0, p0340 = 1 is also called automatically.
After p1900 = 1, 2, p0340 = 3 is also called automatically.
• Integer8 I8 8-bit integer
• Integer16 I16 16-bit integer
• Integer32 I32 32-bit integer
• Unsigned8 U8 8 bits without sign
• Unsigned16 U16 16 bits without sign
• Unsigned32 U32 32 bits without sign
• FloatingPoint32 Float 32-bit floating point number