Catalog
New Interactive
PDF HVAC catalog
usa.siemens.com/hvac
Variable Frequency Drives
C-5
Climatix
Description
The Climatix VFD series is designed specically for use
in new or existing rooftop unit fan applications to provide
the energy efciency needed in an easily integrated,
compact, cost-effective VFD. It leverages the Climatix
RT controller to simplify commissioning, monitoring, and
troubleshooting.
Features
Compact Form
Designed to t nicely in tight spaces with a size 40%
smaller than other VFDs – ideal for RTU retrots.
Conformal Coated PCBs
Durable in harsh environments, the Climatix VFD printed
circuit boards are built to withstand dust and moisture
build-up.
Ease of Use
●
Easy commissioning with Climatix mobile app
●
Compatible with existing induction motoror permanent
magnet motors
●
VFD conguration for induction motors with10 or fewer
parameters (25 or fewer forpermanent magnet motors)
●
Real-time status monitoring with pre-conguredClimatix
IC dashboards
●
Easy access to boards via screwless front cover
●
Removeable fan for easy maintenance
●
Flexible mounting options for easy installation
Additional Features
●
Built-in Safe Torque Off (STO)
●
Multi-motor control – up to 4 motors
●
Built-in PID
●
Phase loss protection
●
Plenum rated
●
DC braking
●
Operating temperature -4º to 122º F
(-20º to 50º C) without derating
●
Certications: UL, CE, RCM, TUV
(SIL 2),RoHS, REACH
Accessories
●
Replacement fan kit VFD frames B-E
●
EMC lter
●
Remote mounting kit
●
Line / load reactors
●
DC choke
Climatix Variable Frequency Drives
Variable Frequency Drives
C-1
usa.siemens.com/hvac
Variable
Frequency Drives
DATE PAGE Descriptionofedits
Introduction C-3
ClimatixVariableFrequencyDrives RT A6V12394104 C-5
BT300HVACDrives BT300 149-711/154-126 C-11
BT300HVACDrivesConventionalBypass(C-Bypass)Options BT300 154-126/154-128 C-23
BT300HVACDrivesElectronicBypass(E-Bypass)Options BT300 154-126/154-129 C-29
BT300VFDNEMAType3RDriveandBypass BT300 154-126 C-35
C-39
Table of Contents
1
usa.siemens.com/hvac
Table of Contents
Application Matrix
A-5
Reference
A-6
Selection Tables
A-16
Pressure Independent Control Valves
A-81
Zone Valves
A-115
Powermite Globe Valves A-129
MZ Series Globe Valves A-131
MT Series Globe Valves A-141
Flowrite Globe Valves A-165
Two- and Three-Way Ball Valves A-205
Six-Way Ball Valves A-219
Magnetic Valves A-225
Refrigeration Valves A-243
Angle/Flared/Sequence/Changeover Service Valves
for Specialized Applications A-263
Resilient Seat Buttery Valves A-275
Accessories and Service Kits A-291
OpenAir
TM
Electronic Damper Actuators B-3
Pneumatic Damper Actuators B-65
Accessories and Service Kits B-77
Climatix VFD C-5
BT300 HVAC Drives C-11
BT300 HVAC Drives Conventional Bypass C-23
BT300 HVAC Drives Electronic Bypass C-29
BT300 VFD NEMA Type 3R Drive and Bypass C-35
Accessories and Service Kits. C-39
Communicating Thermostats D-3
Non-Communicating Thermostats D-11
Electric Thermostats for Specialized Applications D-17
Accessories and Service Kits D-25
Temperature & Relative Humidity Sensors E-3
Air Quality Sensors E-29
Pressure / Differential Pressure / Flow Sensors E-33
Miscellaneous Sensor E-43
Power Metering Equipment E-47
Accessories & Service Kits E-59
Pneumatic Room Thermostats — Powerstar F-3
Pneumatic Room Thermostats — D Series F-17
Pneumatic Thermostats for Specialized Applications F-19
Pneumatic Receiver-Controllers F-27
Pneumatic Transmitters F-31
Pneumatic Auxiliary Equipment F-37
Controls Cabinet F-47
Switches F-49
Relays F-61
Pneumatic Equipment F-79
Accessories and Service Kits F-83
Introduction G-3
Complete Solution G-6
Ordering Information G-7
In the Table of Contents
(TOC), click on any of
the page numbers to
navigate to that page.
Click on the colored page
number square to jump
back to that section's TOC.
Click on the Siemens logo
at the bottom of any page
to navigate back to the
main catalog TOC
on page 1.
Click on any web
link to visit that
product online.