8.4 Log sheet for programmed user functions
Installation: …………………………………………………………………………………………………… Selected pre-setting: …………
Basic programming steps
Step Function Factory setting (Default) Individual setting
1 Timer V1 0.5min min: .....................
2 Timer V2 2min min: .....................
3 Processing of zone Alarm (zone type) via Timer V1/V2 Option 1, zone: .............................
Option 2, zone: .............................
Option 3, zone: .............................
Option 4, zone: .............................
4 LED activation mode
LED Remote transmission
LED Alarm
LED System part disabled mode manned
Resound or not on new alarm
on in state RT-Alarm only
alternating while V1/V2 run
on in manned
resound on new alarm
………………………………………
………………………………………
………………………………………
………………………………………
5 Activation mode of control lines 1 – 6
Control line 1
Control line 2
Control line 3
Control line 4
Control line 5
Control line 6
Continuous Alarm 1/ 2 until reset
Continuous Alarm 1/2 until reset
………………………………………
………………………………………
………………………………………
………………………………………
………………………………………
………………………………………
6 Measures against false alarms
alarm verification
zone disabled in mode manned
no
no
active on zone: .............................
active on zone: .............................
7 Control lines on Alarm active Option 1, zone: .............................
Option 2, zone: .............................
Option 3, zone: .............................
Option 4, zone: .............................
8 Special zone parameters
behavior on immediate Alarm after Reset
driver output per zone
renewed Alarm
active on Alarm
Option 1, zone: .............................
Option 2, zone: .............................
Option 3, zone: .............................
Option 4, zone: .............................
9 Not used
10 Detector line evaluation on line short or line
break
short/break = Fault Option 1, zone: .............................
Option 2, zone: .............................
Option 3, zone: .............................
Option 4, zone: .............................
11 Cross-zoning no Option 1, zone: .............................
Option 2, zone: .............................
Option 3, zone: .............................
12 Access code (password)
operating access
4, 2, 3, 3
………………………………………
13 Special PMI parameters
reminder beep on fault and system part
disabled
Fault messages to be Reset
Suppress battery fault
no
must not be reset
no
………………………………………
………………………………………
………………………………………
14 Not used
15 Special parameters
external Acknowledge and Reset
zones with special disabling procedure
Remote transmission on operating access
all zones with option 1 in step 3 react like
option 4
always possible
no
no
no
………………………………………
………………………………………
………………………………………
………………………………………
16 Programmable control input initiate RT-Fault ………………………………………