User's Manual

All rights reserved SIMATIC IPC427D
© Copyright Siemens AG 2013
2/4
Technical specifications SIMATIC IPC427D
General features
Design • DIN rail mounting
• Wall mounting
• Portrait mounting
Processor • Intel Celeron 827E 1.4 GHz,
1,5 MB SLC
• Intel Core i3-3217UE 1.6 GHz,
3 MB SLC
• Intel Core i7-3517UE 1.7 GHz,
4 MB SLC
Main memory Memory modules without ECC:
• 1 GB DDR3-SDRAM SODIMM
• 2 GB DDR3-SDRAM SODIMM
• 4 GB DDR3-SDRAM SODIMM
• 8 GB DDR3-SDRAM SODIMM
Memory modules with ECC:
• 4 GByte DDR3-ECC SODIMM
• 8 GByte DDR3-ECC SODIMM
Free slots for expansions Up to 2 x PCIe cards, depending
on enclosure design (1 x PCIe x4
and 1 x PCIe x1)
Graphics • Integrated Intel HD2000 or
HD4000
• DVI resolution of 640 x 480 pix-
els up to 1920 x 1200 pixels
Maximum display port resolution
1920 x 1200 pixels
Graphics memory is occupied in
the main memory
(UMA dynamic)
Power supply 24 V DC (-20% / +20%) max. 4 A
Rated conditions Fan-free operation
Operating systems
Available • Without
Windows Embedded Standard 7
• Windows 7 Ultimate MUI
Project-specific •Linux
• QNX
•VxWorks
Drives and storage media
CFast card • 2 GB optional or
• 4 GB optional or
• 8 GB optional or
• 16 GB optional
Hard disk 2.5", 250 GB, SATA
Solid-State Drive (SSD) 2.5"; 80 GB Standard,
50 GB High-Endurance
USB stick External, can be connected via
USB port
Interfaces
Serial • COM1 (RS 232)
• COM2 (RS 232); optional
Graphics • DVI-I: Can be used as DVI or
VGA
• DPP++: Display port, DVI via
DPP-to-DVI adapter
USB 4 x USB 3.0, max. 2 high-current
at the same time, downward-
compatible with USB 2.0/1.1
Ethernet • 2 x RJ45 (10/100/1000 MBit/s)
teaming-capable or
• 1 x RJ45 (10/100/1000 MBit/s)
with PROFINET versions
PROFIBUS DP 12 Mbit/s (isolated, compatible
with CP 5622), optional
PROFINET 3 x RJ45 (10/100 Mbit/s),
CP 1616 onboard, optional
CAN interface Optional
Keyboard, mouse Connection via USB port
Advanced device functions
Temperature • When permitted operating tem-
perature range is exceeded
• Warnings can be analyzed by
application program (local, via
LAN)
Watchdog • Monitoring function for program
execution
Restart can be parameterized in
the event of a fault
• Warnings can be analyzed by
application program (local, via
LAN)
LED display 4 LEDs for displaying system
status, 3 of these can be
programmed by the user
Short-term voltage dips Up to 15 ms buffer time at full
load
Buffer memory 512 KB MRAM 1 optional
© Siemens AG 2013