Technical data

Figure 8: 10BASE-T and 100BASE-TX Interface Circuit Example 2
Table 46 shows some alternatives for the magnetics used in the previous circuits.
Manufacturer Type Remarks
Pulse Engineering H1102
50
50
10
50
50
10
12.4k
75
75
75
75
10 nF
10 nF
10 nF / 2 kV
3.3 V
AGND
AGND
Case GND
ERTEC 200
P(2:1)TxP
P(2:1)RxN
P(2:1)TxN
P(2:1)TxP
EXTRES
RJ45
1
2
4
5
3
6
7
8
Unmarked resistors: 1/16 W and 1% tolerance
Resistors marked with „
•“
:
1/8 W and 1% tolerance
See Table 46
single channel, 0...70°C operating temperature
Pulse Engineering HX1188 single channel, -40...85°C operating temperature
Pulse Engineering H1270 dual channel, 0...70°C operating temperature
Pulse Engineering HX1294 dual channel, -40...85°C operating temperature
Table 46: Examples for Magnetics Selection
In applications, that do not use the 100BASE-FX mode, the related inputs P(2:1)RDxN, P(2:1)RDxP,
P(2:1)SDxN and P(2:1)SDxP should be connected to analog GND, while the related outputs P(2:1)TDxN
and P(2:1)TDxP should be left open. Figure 9 shows the circuit for this case.