2.9 Support for Commissioning Problems
No. Problem Solution
1 Download with FTP server does not take
place. The following message is displayed
on the terminal:
Error loading file: errno = 0x3c.
Can't load boot file!! or
The following message is displayed on the
FTP server:
Socket error 10054 while sending data
Check whether the FTP server has been started and EB200
has been selected in the SecurityÆ User….. menu. If not,
select EB200 and confirm. Reset the evaluation board with the
Reset button.
2 Device is not visible on the bus for HW
Config
Check the power up message to see if a valid IP address has
been set. If so, ping the device to see whether it can be
accessed on the bus and whether the TCP/IP stack is running.
If available, trace the bus traffic with a packet sniffer.
3 Connection is not established between
controller and device
Check whether the station name in Figure 18 matches the
device name
in Figure 4/5. If not, assign names as described
in Section
2.5.2
Table 2: Overview of Possible Problems when Commissioning Device