User guide

[VxWorks Boot]: ^c
'.' = clear field; '-' = go to previous field; ^D = quit
boot device : ifeast0
processor number : 0
host name : xena
file name : vxWorks.st vxworks.stripped
inet on ethernet (e) : 192.168.0.9 192.168.10.2
inet on backplane (b):
host inet (h) : 192.168.0.66 192.168.10.1
gateway inet (g) :
user (u) : boot eb200
ftp password (pw) (blank = use rsh): boot eb200
flags (f) : 0x0 0x8
target name (tn) : ertec200sk
startup script (s) :
other (o) :
Figure 16: Changing Boot Parameters of EB 200 on Message Terminal
Modified parameters are stored in the Flash memory and can be displayed again with p.
Adjust MAC-Address
In delivery state a Default-MAC-Address is stored in the flash of the EB200. This MAC-Address is the same on all
EB200. A label with a unique MAC-Address is placed on the solder site of EB200 near the debug port (X5).
This unique MAC-Address must be stored in the flash of EB200. Make following actions:
Change MAC-Address
Action 1
Press the button
“N”
Following text is displayed on the terminal:
[VxWorks Boot]: N
Current Ethernet Address is: 08:00:06:02:01:00
Modify all 6 bytes (board unique portion) of Ethernet Address.
The first 3 bytes are manufacturer's default address block.
08- 08
00- 00
06- 06
02- 02
01- 01
00- 00
08-
Copyright © Siemens AG 2008. All rights reserved. 25 DK_ERTEC200_PNIO_Description