User guide

2.8.5 Compiling a PROFINET IO Device Example Application
1. Start Tornado and open the Tornado Workspace devkit_eb200.wsp
2. Select the Tornado Project devkit_eb200. Following window will be opened:
The Tornado Projekt „devkit_eb200
“ consists 2 projects
Prelink_PNIO Files Æ project for PROFINET IO Stack and system adaptation
application Files Æ project for PROFINET IO application
and the Prelink to create an executable VxWorks Image
eb200_devkit Files Æ Prelink for executable PROFINET IO Image.
3. After changes are made in a projects you should compile all projects again. Select all project in
succession and activate in the menu bar „Build“ Æ „Build“. A new prelink will be created for all projects
which concern the changes.
4. If step 3 was done an executable vxworks image must be created. Select the prelink „eb200_devkit
Files„ and activate „Build“ Æ „Rebuild All“ in the menu bar. The created file called vxworks is stored in
the \Tornado2.2\target\proj\eb200_ devkit\default\ directory.
If changes are made to this project, steps 3 to 4 must be repeated to create a new file that can be downloaded.
Copyright © Siemens AG 2008. All rights reserved. 20 DK_ERTEC200_PNIO_Description
Technical data subject to change Version 3.0.0