User guide

(3) Connect CPU319 to
device
(1) Connect PC(COM1) to
RS232 of EB200
(2) Connect Tornado-
Shell/FTP server to EB200
vi
a
E
t
h
e
rn
et
Figure 1: PROFINET IO Device with EB 200 in a Minimum Configuration
The following cables are connected for downloading:
Zero modem cable from the RS232 interface of the EB 200 to the COM1 interface of the PC (1).
Crossed Ethernet cable from the Ethernet debug interface of the EB 200 to the FTP interface of the PC
(2).
Ethernet cable between the CPU 319 and the EB 200 to the test of the device example (3).
A terminal and the FTP sever are started for the download. The device software is downloaded automatically.
The required power supplies of the different devices are not shown in the figure.
2.4 Installation of STEP 7/NCM PC and the EB 200 GSD File
This section describes the installation of the required software tools, including PNIO expansions. We recommend
that you perform the following steps in the order indicated.
1. Install the specified version of STEP 7 or NCM PC and familiarize yourself with its operation, if you
have not already done so. For information about this procedure, refer to the STEP 7/NCM PC
documentation.
2. Copy following GSD file from the DK-ERTEC 200 PN IO CD V3.0
for SIMATIC MANAGER the GSD file GSDML-V2.1-Siemens-ERTEC200Devkit-
YYYYMMDD.xml to the directory <Your STEP 7 installation directory>
\Step7\S7Data\GSD.
for NCM PC the GSD file GSDML-V2.0-Siemens-ERTEC200Devkit-YYYYMMDD.xml to
the directory <Your NCM PC installation directory> \SIMATIC.NCM\S7Data\GSD.
NOTE: For the GSD-Filename YYYYMMDD means Year / Month / Day
3. Copy the bitmap files associated with the GSD file from the DK-ERTEC 200 PN IO V3.0 CD
for SIMATIC MANAGER the bitmap files GSDML_002A_ERTEC200DEVKitV10.bmp und
GSDML_002A_ERTEC200DEVKitV22.bmp to the directory <Your STEP 7 installation
directory> \Step7\S7Data\NSBMP.
for NCM PC the bitmap files GSDML_002A_ERTEC200DEVKitV10.bmp und
GSDML_002A_ERTEC200DEVKitV20.bmp to the directory <Your NCM PC installation
directory> \SIMATIC.NCM\S7Data\NSBMP.
4. Start SIMATIC Manager
or NCM PC Manager by creating a new STEP 7 project, for example. Now
update the catalog in HW Config/NCM PC Config
with the Options Æ Catalog menu command. You
will now find the device in the standard hardware catalog under:
PROFINET IO\ IO\ DevKit\ ERTEC 200 developmentkit (see figure below).