Technical data

Copyright © Siemens AG 2013. All rights reserved. 31 EB 200P Manual
Technical data subject to change Version 1.0.1
6.4 Sync connector
For synchronization measurement the BNC connector is assembled and alternatively the 3 pin connector as assembly
option. Signals on 3pin connector are RS485 signals. In the following table pin outs of sync connectors are described.
Connector name: X2
Connector type: BNC
Signal Pin Signal
BNC
Tip
Sync In/Out*1
Shield GND
3 pin
connector
1
Sync RS485 P
2 Sync RS485 N
3 GND via100k
Table 22 Pin assignment of external synchronization connector
Note: *1 Configured by jumper at one time can be connected only input or output
6.5 USB-UART Interface
For UART to USB conversion a convertor from TI is assembled. For USB connection is used mini B connector. In the
following table pin out of USB connector is described.
Connector name: X11
Connector type: USB Mini-B connector
Signal Pin
VBUS
1
D-
2
D+ 3
ID (NC}
4
GND 5
Table 23 Pin assignment of USB Mini-B connector
6.6 EMC interface
To connect additional devices to the EMC bus, Mictor 38 WAY sockets type 5767054 are prepared on EB 200P. In the
following table pin out of EMC connectors is described. This interface is behind level shifters and runs at 3.3V .
Note:
To use external EMC Peripherals it is necessary to assemble EMC data level shifter to EB 200P (D16,
D17) and add control signal logic (R415, R416). This is application depending.
Connector name: X80/X81
Connector type: 38-pin MICTOR connector