Technical data

B46 M Ground A46 LBU_DB13 13-bit data bus
B47 LBU_DB12 12-bit data bus A47 LBU_DB11 11-bit data bus
B48 LBU_DB10 10-bit data bus A48 M Ground
B49 M Ground A49 LBU_DB09 9-bit data bus
B50 - Key A50 - Key
B51 - Key A51 - Key
B52 LBU_DB08 8-bit data bus A52 LBU_BE0_N Command/Byte0 Enable
B53 LBU_DB07 7-bit data bus A53 +3.3 V Supply
B54 +3.3 V Supply A54 LBU_DB06 6-bit data bus
B55 LBU_DB05 5-bit data bus A55 LBU_DB04 4-bit data bus
B56 LBU_DB03 3-bit data bus A56 M Ground
B57 M Ground A57 LBU_DB02 2-bit data bus
B58 LBU_DB01 1-bit data bus A58 LBU_DB00 0-bit data bus
B59 +Vio I/O supply A59 +Vio I/O supply
B60 - Reserved A60 - Reserved
B61 +5 V Supply A61 +5 V Supply
B62 +5 V Supply A62 +5 V Supply
Table 13: Pin Assignment for LBU Interface
Key = Milling for PCI connector
7.3 External DC Power Supply
In stand-alone mode, the EB 200 must be supplied with an external regulated 6-9 VDC/1,5 A power supply by
means of a connector in the front panel.
Connector name: X2
Connector type: Mini-DC power jack 3.5/1.3 mm
Pin No. Signal Name Function
1 DC Potential 6-9 V
2 M Ground 6-9 V
Table 14: Pin Assignment for External DC Supply
Copyright © Siemens AG 2010. All rights reserved. 33 EB 200 Manual
Technical data subject to change Version 1.1.4