Technical data
Signal Name
Function 1
LBU
Config(6,5,2)
= xx0b
Alternative
Function 2
PHY-Debug
Config(6,5,2)
= 011b
Alternative
Function 3
ETM -Trace
Config(6,5,2)
= 101b
Alternative
Function 4
Reserved
Config(6,5,2)
= 111b
IO Function
(Reset): see
Config (6,5,2))
Int.
Pull-
Remarks
LBU_A16 GPIO32 GPIO32 I/B/B (GPIO:I) up LBU or GPIO
LBU_A17 GPIO33 GPIO33 I/B/B (GPIO:I) up LBU or GPIO
LBU_A18 GPIO34 GPIO34 I/B/B (GPIO:I) up LBU or GPIO
LBU_A19 GPIO35 GPIO35 I/B/B (GPIO:I) up LBU or GPIO
LBU_A20 GPIO36 GPIO36 I/B/B (GPIO:I) up LBU or GPIO
LBU_SEG_0 GPIO37 GPIO37 I/B/B (GPIO:I) up LBU or GPIO
LBU_SEG_1 GPIO38 GPIO38 I/B/B (GPIO:I) up LBU or GPIO
LBU_CS_R_N GPIO39 GPIO39 I/B/B (GPIO:I) up LBU or GPIO
LBU-Mode: Chip select for
accesses to paging
configuration register
LBU CS_M_N GPIO40 GPIO40 I/B/B (GPIO:I) up LBU oder GPIO
LBU-Mode: Chip Select für
ERTEC200-Resourcen
LBU_D15 GPIO41 GPIO41 B/B/B (GPIO:I) up LBU or GPIO
LBU_RDY_N GPIO42 GPIO42 O/B/B (GPIO:I) up LBU or GPIO
LBU-Mode: LBU Ready
signal: Polarity dependent
on input pin
LBU_POL_RDY;
Output (driver always
enabled);
LBU_IRQ0_N GPIO43 GPIO43 O/B/B (GPIO:I) up LBU or GPIO
LBU-Mode:
Low active interrupt;
No open drain
LBU_IRQ1_N GPIO44 GPIO44 O/B/B (GPIO:I) up LBU or GPIO
LBU-Mode:
Low active interrupt;
No open drain
Table 7: GPIO [44:32] on EB 200 as Alternative Function
Signal description: I: Input O: Output B: Bidirectional P: Power supply
Up: Internal pull-up Dn: Internal pull-down (I): Status during reset
_N at end of signal name means: Signal is Low active Example: LBU_IRQ0_N
Example of IO Function: B/O/O/I/ (I) Function 1 = Bidirectional, Function 2 = Output, Function 3 = Output, Function 4 =
Input, (I) = IO Function during RESET = Input
Note: The GPIO[44:32] are only available as Inputs on EB200, if alternative function 2 or 3 is selected.
Copyright © Siemens AG 2010. All rights reserved. 18 EB 200 Manual
Technical data subject to change Version 1.1.4