Electrical Lean Switch Installation Instructions

Diagnostics over Industrial Ethernet
Industrial Ethernet
54
A5E00152007-03
2. The component tree now contains a list of all ELS devices that have been
found.
Select one of the ELS devices in the component tree by double-clicking on it.
The folder of this ELS is opened and a further icon appears. Click on this icon.
The data of the interface is displayed in the data window (Figure 6-7). Data not
displayed in gray can be modified.
Figure 6-7 Component View
MAC Address
Displays the MAC address of the ELS in hexadecimal form. The MAC address
cannot be changed.
Obtain IP address from DHCP server
Changes manual configuration of the ELS to automatic configuration using
DHCP.
Caution: This resets the device to its original settings. All user-defined settings
are deleted.
Assign IP parameters
Changes automatic configuration using DHCP to manual configuration of the
ELS.
MAC Address
IP Address