Operating instructions
Technical specifications 
  SCALANCE W788-xPRO / W74x-1PRO/RR 
46  A5E02280448-02, Release 11/2008 
Interfaces 
Note 
Bridging a power outage is possible only with an input voltage of 24 V DC (-15% . . . 
+20%). 
Power  • M12 connector 
(24 V DC, 48 V DC) 
• Energy contacts in the hybrid 
connector 
(24 V DC, 48 V DC) 
• RJ-45 socket Power over Ethernet (48 
V DC) 
2 supplies 24 V DC (24 V DC, 48 V DC)
safety extra-low voltage (SELV). 
The following applies to all named power 
contacts: 
Power supply cables isolated according 
to IEEE 802.3af, isolation resistance > 2 
Mohms. 
Back up  IE IP 67 hybrid connector 
R-SMA antenna sockets 
(2 x or 4 x with the 788-2PRO) 
Electrical data 
Power consumption  < 10 W 
Construction 
Dimensions without antennas 
(W x H x L) 
125 mm x 88 mm x 108 mm 
Weight  approx. 1050 g 
Permitted ambient conditions 
Operating temperature  -20°C to 60°C 
Transport/storage temperature  -40°C to 70°C 
Degree of protection  Tested to IP65 