s SIMATIC NET A5E02280448-02 Release 11/2008 Operating Instructions (Compact) SCALANCE W788-1PRO SCALANCE W788-2PRO SCALANCE W788-1RR SCALANCE W788-2RR SCALANCE W744-1PRO SCALANCE W746-1PRO SCALANCE W747-1RR A5E02280448-02 © SIEMENS AG 2008 Subject to change (Access Point) (Dual Access Point) (Access Point IPCF) (Dual Access Point IPCF) (Ethernet Client Module) (Ethernet Client Module) (Ethernet Client Module IPCF)
Bitte beachten Sie die Warnhinweise und zusätzlichen Informationen in der Betriebsanleitung (kompakt) in Ihrer Sprache im Internet: http://support.automation.siemens.com/ww/view/at/18690255 http://support.automation.siemens.com/ww/view/ch/18690255 http://support.automation.siemens.com/ww/view/de/18690255 http://support.automation.siemens.com/ww/view/li/18690255 http://support.automation.siemens.
http://support.automation.siemens.com/ww/view/hk/18690255 http://support.automation.siemens.com/ww/view/sg/18690255 Kérjük, vegye figyelembe az Interneten található magyar nyelvű használati utasításban (kompakt) olvasható figyelmeztető utasításokat és a kiegészítő információkat! http://support.automation.siemens.com/ww/view/hu/18690255 Vinsamlegast athugið varúðarábendingar og viðbótarupplýsingar í notendahandbókinni (stytt útgáfa) á Netinu: http://support.automation.siemens.
Legal notices Information on the safety notices and correct usage Concept of the warning notices This manual contains notices which you should observe to ensure your own personal safety, as well as to protect the product and connected equipment. Notices relating to your personal safety are highlighted by a warning triangle; notices relating to property damage only do not have a warning triangle. Warnings in descending order according to the degree of danger are shown as follows.
Legal notices Qualified personnel The device/system described here must only be set up and operated in conjunction with this documentation. Only qualified personnel should be allowed to install and work on this equipment/system. Qualified persons in the sense of the safety-related notices in this documentation are defined as persons who are authorized to commission, to ground, and to tag circuits, equipment, and systems in accordance with established safety practices and standards.
Table of contents Introduction .............................................................................................................. 9 Information on the Operating Instructions (compact) SCALANCE W788xPRO/RR and W74x-1PRO/RR .......................................................................9 Type designations................................................................................................10 Description .............................................................................
Table of contents Permitted antennas..............................................................................................54 Certification ............................................................................................................ 57 Approvals for the SCALANCE W788-xPRO/RR and 74x-1PRO/RR ...................57 National approvals SCALANCE W-700 ...............................................................
Introduction Introduction Information on the Operating Instructions (compact) SCALANCE W788-xPRO/RR and W74x-1PRO/RR Validity of the Operating Instructions (compact) These Operating Instructions (compact) cover the following products: ● SCALANCE W788-1PRO ● SCALANCE W788-2PRO ● SCALANCE W788-1RR ● SCALANCE W788-2RR ● SCALANCE W744-1PRO ● SCALANCE W746-1PRO ● SCALANCE W747-1RR These Operating Instructions (compact) apply to the following software version: ● SCALANCE W788-xPRO/RR or W74x-1PRO/RR with firmwar
Introduction Type designations Abbreviations used The information in the manuals for the SCALANCE W-700 product family often applies to more than one product variant. In such situations, the designations of the products are shortened to avoid having to list all the type designations. The following table shows how the abbreviations relate to the product variants. Product group The designation . . . stands for . . .
Introduction Product group The designation . . . stands for . . .
Description Description Components of the product The following parts belong to the consignment of the SCALANCE W788-xPRO/RR or W74x-1PRO/RR: ● SCALANCE W788-xPRO/RR or W74x-1PRO/RR ● 2 OMNI antennas ANT795-4MR ● 1 IE IP 67 hybrid plug-in connector ● 1 protective cap for the M12 socket ● 2 (or 4 with SCALANCE W788-2PRO or SCALANCE W788-2RR) sealing plugs for the R-SMA sockets ● 1 SIMATIC NET Industrial Wireless LAN CD with the Operating Instructions for the SCALANCE W788-xPRO/RR and W74x-1PRO/RR ● 1 Operat
Description L1 F L2 P1 R1 SCALANCE W74x-1xx L1 F L2 P1 R1 SCALANCE W788-1xx Figure 2-1 14 F L1 R2 L2 P1 R1 SCALANCE W788-2xx LEDs of the SCALANCE W788-xPRO/RR or W74x-1PRO/RR SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008
Description LED Color Meaning P1 Yellow Data transfer over the Ethernet interface (traffic). Green There is a connection over the Ethernet port. (Link) Flashing yellow PRESET-PLUG detected. Yellow/green PRESET function completed successfully. Flashing green "Flashing" enabled over PST. L2 Green Power supply over the hybrid connector X1 (PoE or energy contacts). R1 Yellow Data transfer over the first WLAN interface.
Description LED Color Meaning R2 Yellow W788-xPRO/RR in access point mode: Data transfer over the second WLAN port. W788-xPRO/RR in client mode or W74x-1PRO/RR: The LED is always off because the 2nd interface is not available in client mode. Green W788-xPRO/RR in access point mode: The WLAN interface is initialized and ready for operation. W788-xPRO/RR in client mode or W74x-1PRO/RR: The LED is always off because the 2nd interface is not available in client mode.
Description Reset button Functions of the reset button The reset button is on the rear of the device below the sealing screw directly beside the C-PLUG and has several functions: ● Restart of the device To restart the device, press the Reset button. ● Loading new firmware If the normal procedure with the Load & Save menu of Web Based Management does not work, the reset button can be used to load new firmware. This situation can occur if there was a power outage during the normal firmware update.
Mounting Mounting Securing the housing Grounding terminal WARNING To operate the SCALANCE W788 safely, the housing must make contact with a chassis ground cable. Do not use the SCALANCE W788 without a ground cable connected. The ground cable can be connected to one of the securing screws. To allow this, several of the screw contact surfaces in the housing do not have a powder coating. You will find these contact surfaces on the right-hand side of the housing (when looking at the front of the housing).
Mounting CAUTION Premature aging of the device and cables due to UV radiation For applications outdoors, the use of the hardware SCALANCE W786 is advisable due to its greater suitability. Protect the SCALANCE W788-xPRO/RR or W74x-1PRO/RR from direct sunlight by providing suitable shade. This avoids unwanted heating of the device and prevents premature aging of the device and cabling. When operating the SCALANCE W outdoors, it must be mounted so that it is protected from UV.
Mounting Drilling template for the SCALANCE W788-xPRO/RR and SCALANCE W74x-1PRO/RR Drill holes for wall mounting 125 115 90 80 5 5 4 SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 21
Connecting up Connecting up Connectors for external antennas and power supply Hybrid female connector and M12 male connector The SCALANCE W788-xPRO / W788-xRR / W74x-1xx is attached to Ethernet via a hybrid socket on the front of the housing (position A in the figure). This port also has contacts for the operating voltage.
Connecting up D A B Figure 4-1 C Connectors of the SCALANCE W788-xPRO/RR or W74x-1PRO/RR. The additional antenna connectors (position C) only exist for the types W788-2PRO and W788-2RR. As an alternative or in addition to this, you can also use the M12 plug for the power supply (position B in the previous figure). You can fit additional antennas to the sides of the SCALANCE W788-2PRO and SCALANCE W788-2RR with an antenna cable (position C in the previous figure).
Connecting up Arrangement of interfaces and connectors Note The distance between the antennas of the various WLAN interfaces must be at least 1 m. NOTICE Terminating resistor Each WLAN interface has two antenna connectors. If you use only one connector, make sure that you connect a terminating resistor to the second connector to ensure trouble-free operation of the SCALANCE W788-xPRO/RR or W74x1PRO/RR.
Connecting up Replacing the C-PLUG Procedure Follow the steps below to replace the C-PLUG of a SCALANCE W788-xPRO/RR or W74x-1PRO/RR: Note In terms of the C-PLUG, the WLAN devices work in two modes: ● Without C-PLUG The device stores the configuration in internal memory. This mode is active when no C-PLUG is inserted. ● With C-PLUG The configuration stored on the C-PLUG is displayed over the user interfaces. In this mode, the internal memory is neither read nor written.
Connecting up Assembling an IE hybrid cable 2 x 2 + 4 x 0.34 with an IE IP 67 hybrid connector Procedure Remove the two inner shells of the universal sealing ring to adapt it to the diameter of the hybrid cable. Push the bushing, washer, adapted universal sealing ring and the housing over the cable jacket. Remove the following lengths of cable jacket and shield braid: ● 25 mm for the power leads. ● 30 mm jacket for the data leads (shorten the braid by 11 mm).
Connecting up Arrange the data leads according to the color codes on the splice element. The following table shows the assignment of the data leads. Contact 2 (Orange) Contact 1 (Yellow) Conta (Blue) Contact and color assignment of the splice element.
Connecting up Close the splice element and RJ-45 data module until they lock together. Insert the data module and the splice element into the supplied IDC assembly tool. Press the data module and the IDC assembly tool together to establish the installation piercing connection. Remove the assembled data module from the IDC assembly tool.
Connecting up Position the top shield plate and press it over the cable shield. Position the lower shield plate and press it and the upper shield plate together until they lock together with an audible "click". Arrange the power leads and insert them as far as they will go into the hinge elements of the isolation body. The following table shows the assignment of the power leads.
Connecting up Press each individual hinge element together with the integrated IDC contact. Push the housing over the assembled data module and the insulator body until they lock together (there should be an audible click). Tighten the cable gland. We recommend an open key with a size of 21 mm.
Connecting up Fitting the IE FC TP standard cable 4 x 2 GP to an IE IP 67 hybrid connector Procedure Remove the two inner shells of the universal sealing ring to adapt it to the diameter of the hybrid cable. Push the bushing, washer, adapted universal sealing ring and the housing over the cable jacket. 30 mm 25 mm Remove the following lengths of cable jacket and shield braid: ● 25 mm for the power leads ● 30 mm for the data leads To achieve good shielding, the shield braid must be alt least 30 mm long.
Connecting up Arrange the data leads according to the color codes on the splice element. The following table shows the assignment of the data leads. Wind the shield braid around the data leads. As a result, the shielding of the cable has contact to the shield plate of the splice element that will be fitted later. Contact 2 (Orange) Contact 1 (Yellow) * Conta (Blue) Contact and color assignment of the splice element.
Connecting up Close the splice element and RJ-45 data module until they lock together. Insert the data module and the splice element into the supplied IDC assembly tool. Press the data module and the IDC assembly tool together to establish the installation piercing connection. Remove the assembled data module from the IDC assembly tool.
Connecting up Position the top shield plate and press it over the cable shield. Position the lower shield plate and press it and the upper shield plate together until they lock together with an audible "click". Arrange the power leads and insert them as far as they will go into the hinge elements of the isolation body. The following table shows the assignment of the power leads.
Connecting up Press each individual hinge element together with the integrated IDC contact. Recommendation: Use a small slotted screwdriver (max. 3.5 mm) as a lever. Push the housing over the assembled data module and the insulator body until they lock together (there should be an audible click). Tighten the cable gland. We recommend an open key with a size of 21 mm.
Connecting up Pinning of the M12 male connector Power supply over the M12 connector The M12 male connector on the front of the SCALANCE W7xx has the following pinning: Pin Function Pin 1 24 V DC Pin 2 -- Pin 3 Ground Pin 4 -- Lightning protection, power supply, and grounding Notes on lightning protection WARNING Danger due to lightning strikes Antennas installed outdoors must be within the area covered by a lightning protection system.
Connecting up Note The requirements of EN61000-4-5, surge immunity tests on power supply lines, are met only when a Blitzductor is used with 12 - 24 V DC and 48 V DC: 12 - 24 V DC: VT AD 24V type no. 918 402 48 V DC: BXT ML2 BD S48, Part no. 920245 BXT BAS, Part no. 920300 (base) Manufacturer: DEHN+SÖHNE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D92306 Neumarkt, Germany NOTICE 48 V lightning protector When using the 48 V DC lightning protector, the power supply must be fused with 1 A.
Connecting up Safety extra low voltage WARNING Danger to life from overvoltage, fire hazard SCALANCE W-700 devices are designed for operation with a directly connectable safety extra-low voltage or with the power supply adapters available as accessories (available only for the SCALANCE W786-xPRO device).
Connecting up Grounding CAUTION Damage to the device due to potential differences To fully eliminate the influence of electromagnetic interference, the device must be grounded. There must be no potential difference between the following parts, otherwise the device or other connected device could be severely damaged: ● Housing of the SCALANCE W-700 and the ground potential of the antenna. ● Housing of the SCALANCE W-700 and the ground potential of a device connected over Ethernet.
Connecting up Suitable antenna cables and antennas for SCALANCE W-700 Antenna connector: N-Connect/R-SMA connecting cable The N-Connect/R-SMA male/male flexible connecting cable is available as an accessory for direct connection of an antenna to a SCALANCE W-700.
Connecting up Type Properties Order no. ANT793-8DN Directional antenna 5 GHz, wall mounted 6GK5793-8DN00-0AA6 ANT795-6DN Directional antenna 2.4 / 5 6GK5795-6DN00-0AA6 GHz, wall mounted ANT795-4MR Omni antenna 2.4 / 5 GHz, mounted directly on a SCALANCE W788xPRO/RR or W74x1PRO/RR ANT795-4MS Omni antenna 2.4 / 5 6GK5795-4MS00-0AA6 GHz, mounted directly on a SCALANCE W788xPRO/RR or W784-1xx or W74x-1PRO/RR or W74x1 6GK5795-4MR00-0AA6 ANT792-4DN RCoax antenna 2.
Connecting up Cabling for power supply and Ethernet Suitable cables The following cables are available for connecting a SCALANCE W788-xPRO/RR or SCALANCE W74x-1PRO/RR to the power supply and Ethernet: ● IE hybrid cable 2 x 2 + 4 x 0.34 (order no. 6XV1870-2J) The two data wire pairs are separately shielded. This cable is particularly suitable for assembly with the IE IP 67 hybrid connector. ● IE FC TP standard cable 4 x 2 GP (order no. 6XV1870-2E) In these cable types, two wires are twisted.
Technical specifications Technical specifications Technical specifications for the SCALANCE W788xPRO/RR and W74x-1PRO/RR Device variants The technical specifications of the ● SIMATIC NET SCALANCE W744-1PRO ● SIMATIC NET SCALANCE W746-1PRO ● SIMATIC NET SCALANCE W747-1RR ● SIMATIC NET SCALANCE W788-1PRO ● SIMATIC NET SCALANCE W788-2PRO ● SIMATIC NET SCALANCE W788-1RR ● SIMATIC NET SCALANCE W788-2RR are largely identical.
Technical specifications Interfaces Note Bridging a power outage is possible only with an input voltage of 24 V DC (-15% . . . +20%). Power • M12 connector (24 V DC, 48 V DC) • Energy contacts in the hybrid connector (24 V DC, 48 V DC) • RJ-45 socket Power over Ethernet (48 V DC) 2 supplies 24 V DC (24 V DC, 48 V DC) safety extra-low voltage (SELV). The following applies to all named power contacts: Power supply cables isolated according to IEEE 802.3af, isolation resistance > 2 Mohms.
Technical specifications MTBF information (mean time between failure) MTBF 67 years Transmit power Table 1 Transmit power in IEEE 802.11b mode (2.4 GHz) Data rate [Mbps] P0 [dBm] 1 20 2 20 5,5 20 11 20 Table 2 Transmit power in IEEE 802.11g mode (2.
Technical specifications Table 3 Transmit power in IEEE 802.11a/h mode (5 GHz) Data rate [Mbps] P0 [dBm] 6 17 9 17 12 17 18 17 24 17 36 16 48 15 54 13,5 Receiver sensitivity Table 4 Receiver sensitivity in IEEE 802.11b mode (2.4 GHz) Data rate [Mbps] Pe [dBm] 1 -98 2 -94 5,5 -92 11 -90 Table 5 Receiver sensitivity in IEEE 802.11g mode (2.
Technical specifications Table 6 Receiver sensitivity in IEEE 802.11a/h mode (5 GHz) Data rate [Mbps] Pe [dBm] 6 -90 9 -89 12 -88 18 -86 24 -83 36 -80 48 -75 54 -74 PNIO - performance data Even in the planning phase of a plant, it is important to know the reaction time of IO communication and the delay time for data communication in a PROFIBUS, PROFINET IO or Industrial Ethernet network.
Technical specifications SCALANCE W788 dimension drawing Front view and top view SCALANCE W788 P1 L1 R1 L2 F 6GK5788-1AA60-6AA0 NEC CLASS 2 24V/48V 0.3A/0.15A WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. M3 M2 L3 L2 90 A1 ANTENNA X2 L1 24V/48V WARNING: EXPLOSION HAZARD.
Technical specifications Side view SCALANCE W788 44 105 112 SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 51
Technical specifications Technical specifications ANT795-4MR Mechanical characteristics Connector R-SMA male for connection to SCALANCE W78x or SCALANCE W74x Cover material Polycarbonate Silicone-free Electrical characteristics Frequency range 2.4 ~ 2.4835 GHz 5.15 ~ 5.35 GHz 5.725 ~ 5.85 GHz Impedance 50 ohms Voltage standing wave ratio ≤ 2,0 Return loss ≤ -10 dB Gain at 2.45 GHz 3 dBi Gain at 5.25 GHz 5 dBi Polarization Vertical Ambient temperature - 20 °C....
Technical specifications Dimension drawing ANT795-4MR 6 148 21,2 34,6 SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 13 53
Technical specifications Permitted antennas Accessories for SCALANCE W-700 Note When you select an antenna, keep in mind the national approvals for your SCALANCE W7xx. Characteristics Type Omni Antenna gain / dBi Impedance / Order No.
Technical specifications Characteristics Type Frequency / GHz Antenna gain / dBi Impedance / Order No.
Certification Certification Approvals for the SCALANCE W788-xPRO/RR and 74x-1PRO/RR CE conformity The products SIMATIC NET SCALANCE W788-1PRO SIMATIC NET SCALANCE W788-2PRO SIMATIC NET SCALANCE W788-1RR SIMATIC NET SCALANCE W788-2RR SIMATIC NET SCALANCE W744-1PRO SIMATIC NET SCALANCE W746-1PRO SIMATIC NET SCALANCE W747-1RR in the version put into circulation by Siemens AG conform to the regulations of the following European directive: ● 99/5/EC Directive of the European Parliament and of the Council on rad
Certification ● EN 301893 V1.3.1 Broadband Radio Access Networks (BRAN) - 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.
Certification SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 59
Certification ATEX, cULus and FM approvals The products SIMATIC NET SCALANCE W788-1PRO SIMATIC NET SCALANCE W788-2PRO SIMATIC NET SCALANCE W788-1RR SIMATIC NET SCALANCE W788-2RR SIMATIC NET SCALANCE W744-1PRO SIMATIC NET SCALANCE W746-1PRO SIMATIC NET SCALANCE W747-1RR have the following approvals ● EN 60079-15:2005 EN 60079-0:2006 II 3 G Ex nA II T.. KEMA 07 ATEX 0145X ● c-UL-us: UL 60950-1 CSA C22.2 No. 60950-1 ● c-UL-us for hazardous location*: ISA 12.12.01-2000, CSA C22.2 No. 213-M1987 CL. 1, Div. 2 GP.
Certification Note The specified approvals apply only when the corresponding mark is printed on the product. FCC approval This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Certification ___________________________________________________________________________ Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. ___________________________________________________________________________ This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Certification Note The specified approvals apply only when the corresponding mark is printed on the product. 사용자안내문(제 5 조제 1 항제 1 호관련) 기종별 사용자안내문 A 급 기기 (업무용 방송통신기기) (업무용 방송통신기기) 기기이오니 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다. "당해 무선설비는 전파혼신 가능성이 있으므로 인명안전과 관련된 서비스는 할 수 없음" National approvals SCALANCE W-700 National approvals The following table lists the countries in which the SCALANCE W700 product is approved.
Certification Country Mode Argentina ♦ 11b CH 100 mW Indoor + outdoor 56 60 64 5280 5300 5320 50 mW Indoor + outdoor 149 161 5745 5805 1000 mW Indoor + outdoor 11b 11g g-Turbo 1 13 2412 2472 100 mW Indoor + outdoor 11a 36 64 5180 5320 200 mW Indoor only 149 165 5745 5825 42 5210 50 mW Indoor only 50 58 5250 5290 200 mW Indoor only 152 160 5760 5800 1000 mW Indoor + outdoor 11b 11g g-Turbo 1 13 2412 2472 100 mW Indoor + outdoor 11a 36 48 5180 5240 200 mW Indoor only TP
Certification Country Mode CH Brazil ♦ 11b 11g 11g-Turbo 1 13 2412 2472 11a 36 48 5180 5240 200 mW Indoor only TPC 36 64 5180 5320 200 mW Indoor only DFS+TPC 149 165 5745 5825 1000 mW Indoor + outdoor 11b 11g g-Turbo 1 13 2412 2472 100 mW Indoor + outdoor 11h 36 56 5180 5280 200 mW Indoor only 100 140 5500 5700 11b 1 13 2412 2472 100 mW Indoor only 11h 36 48 5180 5240 100 mW Indoor only 52 64 5260 5320 100 mW Indoor only 149 165 5745 5825 100 mW Indoor only 42 52
Certification Country China Mode CH PWR (EIRP) Use 152 160 5760 5800 100 mW Indoor only 1 13 2412 2472 100 mW Indoor + outdoor 149 165 5745 5825 1000 mW Indoor + outdoor 11b 11g g-Turbo 1 13 2412 2472 100 mW Indoor + outdoor 11a 5180 5240 200 mW Indoor only TPC 36 48 36 64 5180 5320 200 mW Indoor only DFS+TPC 100 140 5500 5700 11b 11g g-Turbo 11a TPC Belgium Denmark Germany Finland Greece United Kingdom Ireland Iceland Italy Liechtenstein Luxembourg The Netherlands Norway Aust
Certification Country Mode CH France 11b 11g g-Turbo Use 2412 2442 100 mW Indoor + outdoor 8 13 2447 2472 100 mW Indoor only 36 48 5180 5240 200 mW Indoor only TPC 5180 5320 200 mW Indoor only DFS+TPC 36 64 100 140 5500 5700 1000 mW Indoor + outdoor 11b 11g g-Turbo 1 13 2412 2472 100 mW Indoor + outdoor 11a 5180 5240 200 mW Indoor only TPC 36 48 36 64 5180 5320 200 mW Indoor only DFS+TPC 100 140 5500 5700 1000 mW Indoor + outdoor 11b 11g 1 13 2412 2472 100 mW Indoor +
Certification Country Mode CH Japan 11b 1 14 2412 2484 100 mW Indoor + outdoor 11g 1 13 2412 2472 100 mW Indoor + outdoor 184 196 4920 4980 200 mW Indoor + outdoor 8 12 16 5040 5060 5080 200 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only 1 2412 200 mW Indoor + outdoor 2 10 2417 2457 1000 mW Indoor + outdoor 11 2462 200 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only 149 165 5745 5825 11a TPC Canada 11b 11g 11a TPC 11a Turbo TPC 68 MHz PWR (EIRP) 42
Certification Country Mode CH Columbia 11b 11g 11a TPC MHz PWR (EIRP) Use 1 2412 200 mW Indoor + outdoor 2 10 2417 2457 1000 mW Indoor + outdoor 11 2462 200 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only 149 165 5745 5825 1000 mW Indoor + outdoor Kuwait 11b 11g g Turbo 1 13 2412 2472 100 mW Indoor + outdoor Malaysia ♦ 11b 11g 1 13 2412 2472 100 mW Indoor + outdoor 11a 56 60 64 5280 5300 5320 200 mW Indoor only 149 165 5745 5825 1000 mW Indoor + outdoor 11b 1
Certification Country Mode CH Russia ♦ 11b 11g 1 13 2412 2472 100 mW Indoor + outdoor 11a 36 48 5180 5240 50 mW Indoor + outdoor 52 64 5260 5320 250 mW Indoor + outdoor 72 140 5360 5700 1000 mW Indoor + outdoor 149 165 5745 5825 1000 mW Indoor + outdoor TPC MHz PWR (EIRP) Use Saudi Arabia 11b 11g g-Turbo 1 13 2412 2472 100 mW Indoor + outdoor Singapore 11b 11g g-Turbo 1 13 2412 2472 100 mW Indoor + outdoor 11h 36 64 5180 5320 100 mW Indoor + outdoor 149 165 5745 5825
Certification Country Mode CH South Africa 11b 11g g-Turbo 1 13 2412 2472 11a 36 48 5180 5240 60 mW Indoor only 36 64 5180 5320 200 mW Indoor only 100 140 5500 5700 1000 mW Indoor + outdoor 1 13 2412 2472 40 mW Indoor + outdoor (RHS power=10 mW/MHz) 149 161 5745 5805 200 mW Indoor + outdoor (RHS power=10 mW/MHz) 11b 11g g-Turbo 1 11 2412 2462 1000 mW Indoor + outdoor 11a 52 68 5260 5340 149 165 5745 5825 52 68 5260 5340 96 140 5480 5700 TPC 11h DFS+TPC South Korea ♦ 11
Certification Country Czech Republic Mode CH 1000 mW Indoor + outdoor 11b 11g g-Turbo 1 13 2412 2472 100 mW Indoor + outdoor 11a 36 48 5180 5240 200 mW Indoor only TPC 5180 5320 200 mW Indoor only DFS+TPC 36 64 100 140 5500 5700 1000 mW Indoor + outdoor 11b 11g g-Turbo 1 13 2412 2472 100 mW Indoor + outdoor 11a 5180 5240 60 mW Indoor only TPC 36 48 36 64 5180 5320 200 mW Indoor only DFS+TPC 11b 11g g-Turbo 1 13 2412 2472 100 mW Indoor + outdoor 11a 36 64 5180 5320 200
Certification Country Mode CH United States of America 11b 11g 11a TPC 11a Turbo TPC MHz PWR (EIRP) Use 1 2412 200 mW Indoor + outdoor 2 10 2417 2457 1000 mW Indoor + outdoor 11 2462 200 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only 149 165 5745 5825 1000 mW Indoor + outdoor 152 160 5760 5800 1000 mW Indoor + outdoor The following notice applies only to the SCALANCE W786-2HPW: NOTICE Before commissioning the SCALANCE W786-2HPW, check that the Hipath Wireless Controller