SCALANCE W786 outdoor access point 1 ___________________ Information on the Internet 2 ___________________ Safety instructions SIMATIC NET Industrial Wireless LAN SCALANCE W786 outdoor access point Operating Instructions 3 ___________________ Introduction 4 ___________________ Description 5 ___________________ Mounting 6 ___________________ Connecting up 7 ___________________ Technical specifications 8 ___________________ Certification 06/2013 A5E02280428-08
Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
Contents 1 Information on the Internet ...................................................................................................................... 5 2 Safety instructions ................................................................................................................................... 7 2.1 3 4 5 6 7 General safety information for the SCALANCE W786 .................................................................. 7 Introduction .........................................
Contents 8 7.3 Permitted antennas ..................................................................................................................... 60 7.4 Radiation patterns diagrams of SCALANCE W786 internal antennas ....................................... 61 Certification........................................................................................................................................... 65 8.1 Approvals for SCALANCE W786 ....................................................
Information on the Internet 1 Bitte beachten Sie die Warnhinweise und zusätzlichen Informationen in der Betriebsanleitung (kompakt) in Ihrer Sprache im Internet: http://support.automation.siemens.com/ww/view/at/10806097 http://support.automation.siemens.com/ww/view/ch/10806097 http://support.automation.siemens.com/ww/view/de/10806097 http://support.automation.siemens.com/ww/view/li/10806097 http://support.automation.siemens.
Information on the Internet 请遵守互联网上用您的语言编写的用户手册(简易版)中的警告信息和附加说明: http://support.automation.siemens.com/ww/view/cn/10806097 http://support.automation.siemens.com/ww/view/hk/10806097 http://support.automation.siemens.com/ww/view/sg/10806097 Kérjük, vegye figyelembe az Interneten található magyar nyelvű használati utasításban (kompakt) olvasható figyelmeztető utasításokat és a kiegészítő információkat! http://support.automation.siemens.
Safety instructions 2.1 2 General safety information for the SCALANCE W786 WARNING Danger from line voltage After removing the housing cover, there is a risk of touching live parts in the area of the connecting terminals of the power supply adapter. Only authorized personnel is permitted to open the device and carry out any work on the open device (e.g.
Safety instructions 2.
3 Introduction 3.1 Information on the Operating Instructions Validity of the Operating Instructions (compact) These operating instructions cover the following products: ● SCALANCE W786-1PRO ● SCALANCE W786-2PRO ● SCALANCE W786-3PRO ● SCALANCE W786-2RR These operating instructions apply to the following software version: ● SCALANCE W786 firmware as of version 4.
Introduction 3.2 Type designations 3.2 Type designations Abbreviations used The information in the manuals for the SCALANCE W-700 product family often applies to more than one product variant. In such situations, the designations of the products are shortened to avoid having to list all the type designations. The following table shows how the abbreviations relate to the product variants. Product group The designation . . . stands for . . .
Introduction 3.2 Type designations Product group The designation . . . stands for . . .
Introduction 3.
4 Description 4.1 Scope of delivery 4.2 LED display Information on operating status and data transfer On the front of the housing, several LEDs provide information on the operating status of the SCALANCE W786: Figure 4-1 The LED display of the SCALANCE W786 Note The "PoE" LED does not exist on devices with a port for FO cable.
Description 4.2 LED display LED Color Meaning L1 Green Power supply over a power supply adapter or the 48 V DC energy contacts of devices with a port for FO cable. PoE Green Power over Ethernet or power over the 48 V DC energy contacts of devices with an RJ-45 port. P1 Yellow Data transfer over the Ethernet interface (traffic). Green There is a connection over the Ethernet port. (Link). Flashing yellow PRESET-PLUG detected. Yellow/green PRESET function completed successfully.
Description 4.2 LED display LED Color Green flashing quickly Meaning Access Point Mode: With 802.11h, the channel is scanned for one minute for primary users before the channel can be used for data traffic. Client Mode: The LED is always off because the 2nd port is not available in client mode. R3 Flashing yellow PRESET-PLUG detected. Yellow/green PRESET function completed successfully. Yellow Access Point Mode: Data transfer over the third WLAN port.
Description 4.2 LED display Note If the LED for the WLAN port is not green when the device starts up, although it is activated, the port is not ready for operation (interface not initialized). The main reason for this is usually that during commissioning of the SCALANCE W78x products, a waiting time of up to 15 minutes can occur when the ambient temperature is below zero. The device is ready for operation at the specified ambient temperature as soon as the LED for the WLAN interface is lit green.
Description 4.3 Reset button 4.3 Reset button WARNING Danger from line voltage Once you have removed the housing cover, there is the danger from line voltage in the area of the connecting terminals on the power supply adapter. Only authorized personnel is permitted to open the device and carry out any work on the open device (e.g.
Description 4.
5 Mounting 5.1 Removing / fitting the housing cover When does the housing cover need to be removed? You can only perform the following activities when the cover is removed. ● You want to screw the SCALANCE W786 to a wall or onto the optional mounting plate. ● You want to connect cables to the SCALANCE W786 for the power supply, for Ethernet or for external antennas. ● You want to insert a PLUG in the device or replace an existing PLUG. ● You want to use the reset button.
Mounting 5.1 Removing / fitting the housing cover Figure 5-1 Removing the cover A Sealing cap B Cover screw C Housing cover Follow the steps below to remove the housing cover: 1. Remove the sealing caps from the housing cover (position A in the figure above) 2. Loosen the screws in the cover (position B in the figure above). 3. Remove the housing cover (position C in the figure above). Fitting the housing cover Fitting the housing cover is carried out in the reverse order.
Mounting 5.2 Connecting up cables 5.2 Connecting up cables Connecting up cables prior to mounting Before you screw a SCALANCE W786 to a wall or to the optional mounting plate, the cables for the power supply, for Ethernet, and, when necessary, for the external antennas must be connected up first. The available options are as follows: Figure 5-2 Side view of a SCALANCE W786 with cables entering from different directions ● The cables are inserted from above (position A in the previous schematic).
Mounting 5.2 Connecting up cables Connecting up FO cables Fiber-optic cables have a minimum bending radius. The cable must not be bent tighter than this bending radius during installation or operation, otherwise the FO cable will be irreperably damaged. Figure 5-3 Connecting up an FO cable For the FO cable, use the second opening from the left in the seal. Cable routing is illustrated in the figure above. For individual cores immediately following the connector, the minimum bending radius is 25 mm.
Mounting 5.2 Connecting up cables Grounding terminal WARNING To operate the SCALANCE W786 safely, the chassis ground connector must have a suitable cable connected. Do not use the SCALANCE W786 without a ground cable connected. The chassis ground connector is located on the rear of the device (M4 thread). Connect the ground cable before you mount the SCALANCE W786 on a wall or on the optional mounting plate. Once the SCALANCE W786 is mounted, the connector is no longer accessible.
Mounting 5.3 Mounting without an adapter (wall mounting only) 5.3 Mounting without an adapter (wall mounting only) Drilling template Note Installation location The following should be noted with regard to the installation location: • Devices with an internal antenna must be aligned according to the characteristics of the internal antenna (refer to the technical specifications of the antenna --> Radiation pattern diagrams).
Mounting 5.3 Mounting without an adapter (wall mounting only) Procedure Figure 5-6 SCALANCE W786 wall mounting Follow the steps below to screw a SCALANCE W786 to a wall: 1. Lead the cables into the housing of the SCALANCE W786 (position A in the figure above). Note the information in the section "Connecting up cables". 2. Secure the SCALANCE W786 to the wall with three screws (position B in the figure above). The screws are not supplied with the device.
Mounting 5.4 Mounting with mounting plate 5.4 Mounting with mounting plate 5.4.1 Fitting the mounting plate to a wall Drilling template Note Installation location The following should be noted with regard to the installation location: • Devices with an internal antenna must be aligned according to the characteristics of the internal antenna (refer to the technical specifications of the antenna --> Radiation pattern diagrams).
Mounting 5.4 Mounting with mounting plate Procedure Secure the mounting plate to the wall with four screws. The screws are not supplied with the device. The type and length of the screws depend on the type of wall.
Mounting 5.4 Mounting with mounting plate 5.4.2 Screwing the cover plate for the cable feedthrough to the mounting plate Protection of the cable feedthrough against strong water jets The cabling of a SCALANCE W786 is led out of the rear of the device. The housing seal is effective only when it is not subjected to water jets. If the device is mounted on a wall, this is the case and no further measures are necessary.
Mounting 5.4 Mounting with mounting plate To screw the cover plate for the cable feedthrough to the mounting plate, follow the steps below: 1. Fit the cover plate on the mounting plate from below until the two lugs (position A in the figure above) engage the lower edge of the mounting plate. 2. Secure the cover plate to the mounting plate with two M4 screws. The screws are supplied with the assembly kit. 5.4.
Mounting 5.4 Mounting with mounting plate 5.4.4 Fitting the mounting plate to a DIN rail NOTICE No DIN rail mounting when used on ships If the SCALANCE W786 is used on ships, the DIN rail mounting is not adequate to hold the device in place. In such cases, mount the SCALANCE W786 on an S7-300 rail or on an S71500 rail. Procedure Figure 5-11 Mounting plate with fittings for DIN rail mounting Follow the steps below to fit the mounting plate to a DIN rail: 1.
Mounting 5.4 Mounting with mounting plate 5.4.5 Fitting the mounting plate to a mast Procedure Figure 5-12 Mounting plate with fittings for mast mounting Follow the steps below to fit the mounting plate to a mast: 1. Feed the fastening straps through the openings in the mounting plate (position A in the figure above). 2. Place the fastening straps around the mast at the required position. 3. Feed the free end of the strap through the quick-release fastener.
Mounting 5.4 Mounting with mounting plate 5.4.6 Fitting/removing the SCALANCE W786 to/from a mounting plate Procedure for mounting the device Figure 5-13 Fitting the SCALANCE W786 to a mounting plate Follow the steps below to fit a SCALANCE W786 to a mounting plate: 1. Lead the cables into the housing of the SCALANCE W786 (position A in the figure above). Note the information in the section "Connecting up cables". 2.
Mounting 5.4 Mounting with mounting plate 3. Push in the SCALANCE W786 until it engages in the notches at the lower edge of the mounting plate (position C in the figure above). Figure 5-14 Screwing a SCALANCE W786 to a mounting plate 4. Screw the SCALANCE W786 using the three M4 screws supplied with the mounting plate (position D in the figure above), tightening torque 1.8 Nm. Procedure for removing the device Follow the steps below to remove a SCALANCE W786 from a mounting plate: 1.
Mounting 5.
Connecting up 6.1 6 Lightning protection, power supply, and grounding Notes on lightning protection WARNING Danger due to lightning strikes Antennas installed outdoors must be within the area covered by a lightning protection system. Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system. When implementing your lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305 standard.
Connecting up 6.1 Lightning protection, power supply, and grounding Note 48 V lightning protector When using the 48 V DC lightning protector, the power supply must be fused with 1 A. Safety extra low voltage WARNING Danger to life from overvoltage, fire hazard The equipment is designed for operation with Safety Extra Low Voltage, SELV by a Limited Power Source, LPS. (This does not apply to 100 V ... 240 V devices.
Connecting up 6.1 Lightning protection, power supply, and grounding Power supply without power grid To operate the device without a connection to the power grid, you can use a solar panel. The company Solis Energy (www.solisenergy.com) offers suitable solutions. The size of the panel required depends on the daily hours of sunlight. The manufacturer provides assistance in selecting the panel. The solar solution must be designed for 15 watts.
Connecting up 6.1 Lightning protection, power supply, and grounding Notes on operating the device in a hazardous area WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2 OR ZONE 2. WARNING EXPLOSION HAZARD DO NOT OPEN WHEN ENERGIZED.
Connecting up 6.1 Lightning protection, power supply, and grounding Special notes for the SCALANCE W786-xPRO/RR Warning Notices cULus haz.loc. This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D; Class I, Zone 2, Group IIC or non-hazardous locations. WARNING - Cat. Nos. EAP-Wx-yy-zx (US installation only): - PLTC cable type and manufacturer shall be specified: Listed (QPTZ), Type 5240U1 (Waterdog PLTC-ER) manufactured by Belden.
Connecting up 6.2 Suitable cables for the SCALANCE W786 6.2 Suitable cables for the SCALANCE W786 Cable specification The following table lists the requirements for a cable depending on the use case. Application Specification Direct 48 V DC supply • Round cable cross-section with 6 to 8 mm diameter. • Permitted tensile load at least 100 N. • UL listing: Type PLTC or ITC • Round cable cross-section with 6 to 8 mm diameter. • Permitted tensile load at least 100 N.
Connecting up 6.2 Suitable cables for the SCALANCE W786 WARNING If temperatures in excess of 70° occur on the cable or at the housing socket, or the temperature at the branching points of the cables exceeds 80°, special measures need to be taken. If the device is operated at an ambient temperature of 55 °C - 70 °C, make sure that you use cables with a permitted ambient temperature of at least 90 °C.
Connecting up 6.3 Connecting the cables 6.3 Connecting the cables Procedure WARNING Danger from line voltage If the housing is not perfectly sealed, there is a danger to life due to the line voltage if the SCALANCE W786 is subjected to spray water or dampness. Make sure that you keep to the following safety rules. • Before connecting up, turn of the power supply.
Connecting up 6.3 Connecting the cables Figure 6-1 Connecting a cable and fitting the strain relief clamps Follow the steps below to connect cables to the SCALANCE W786: 1. Connect the cables to the appropriate contacts. (Position A in the figure above) You have the following options: – Connect cables preassembled with a connector (Ethernet, antennas) by inserting the connector into the appropriate socket. Secure antenna cables by tightening the sleeve nut of the connector (key size SW8).
Connecting up 6.3 Connecting the cables 4. Seal all openings not required for cables with sealing plugs (position D in the figure above). 5. Fit these sealing plugs in a strain relief clamp. The lower surrounding notch must be enclosed by the toothing of the strain relief clamp (as shown in the figure below). Press the strain relief clamp into the housing until the sealing plug is located completely in the opening of the housing seal.
Connecting up 6.4 Connectors for the power supply of the SCALANCE W786 Figure 6-3 6.4 View from above with an FO cable inserted in the strain relief clamp Connectors for the power supply of the SCALANCE W786 Possible power supplies The following power supplies are suitable for the SCALANCE W786: ● 48 VDC direct voltage Use the two-pin connector supplied with the SCALANCE W786. ● 12 - 24 VDC direct voltage Use the power supply adapter 12 - 24 VDC available as an accessory.
Connecting up 6.4 Connectors for the power supply of the SCALANCE W786 Procedure for connecting the supplied connector for 48 VDC Figure 6-4 Position of the opening in the housing for the power supply with the housing cover removed Perform the following steps to connect a 48 VDC cable to a SCALANCE W786: 1. Connect the supplied connector to the 48 VDC cable. The figure above shows the location of the socket in the housing and the contact assignment.
Connecting up 6.5 Connecting a power supply adapter 6.5 Connecting a power supply adapter Input voltage options The optional power supply adapter is available in two versions: ● Power supply adapter for 12 - 24 V DC direct voltage ● Power supply adapter for 100 - 240 V AC alternating voltage Note Applies only to SCALANCE W786-3xx If a SCALANCE W786-3xx is operated with diversity for three antenna pairs, the power for 12 - 24 V DC cannot be supplied redundantly.
Connecting up 6.5 Connecting a power supply adapter NOTICE Exceeding the EMC limit values • SCALANCE W786 with RJ-45 interface with DC power supply adapter or without power supply adapter When using a SCALANCE W786 with RJ-45 connector without a power supply adapter or with a DC power adapter, no additional measures are necessary for use in a residential environment.
Connecting up 6.5 Connecting a power supply adapter Figure 6-6 Using a power supply adapter in a SCALANCE W786 Follow the steps below to fit and connect a power supply adapter: 1. Fit the power supply adapter in the SCALANCE W786 as shown in the figure above. The connector on the rear of the power supply adapter must engage fully in the socket of the housing. The entire rear surface of the power supply adapter must make contact with the inner surface of the SCALANCE W786.
Connecting up 6.5 Connecting a power supply adapter The following applies to the PS791-2AC (AC 100 – 240 V) only: WARNING Danger from line voltage The strain relief clamp may damage the insulation under unfavorable circumstances. You run the risk of encountering danger from line voltage through the strain relief clamp.
Connecting up 6.6 Connection for Industrial Ethernet 6.6 Connection for Industrial Ethernet Device variants With a SCALANCE W786, you have the choice of two Ethernet ports: ● RJ-45 jack ● ST duplex socket for multimode FO cables 1310 nm and a maximum cable length of 3000 m Procedure for connecting an Ethernet cable Figure 6-7 Position of the Ethernet port with the housing cover removed Perform the following steps to connect an Ethernet cable to a SCALANCE W786: 1.
Connecting up 6.7 Connectors for external antennas 6.7 Connectors for external antennas How to connect external antennas Note The distance between the antennas of the various WLAN interfaces must be at least 1 m. Figure 6-8 Position of the ports for external antennas with the housing cover removed For each WLAN port, there are two R-SMA sockets on a SCALANCE W786 to connect external antennas. The figure above shows how the R-SMA sockets are assigned to the WLAN ports.
Connecting up 6.8 Inserting / removing the C-PLUG 6.8 Inserting / removing the C-PLUG WARNING Danger from line voltage Once you have removed the housing cover, there is the danger from line voltage in the area of the connecting terminals on the power supply adapter. Only authorized personnel is permitted to open the device and carry out any work on the open device (e.g. connection and disconnection of lines, operating the reset button, replacing the C-PLUG).
Connecting up 6.8 Inserting / removing the C-PLUG Removing the C-PLUG Follow the steps below to remove a C-PLUG from the device: 1. Turn off the power to the device. 2. Remove the housing cover, see section "Removing/fitting the housing cover". 3. Insert a screwdriver between the front edge of the C-PLUG and the slot and release the C-PLUG. 4. Remove the C-PLUG from the slot. 5. Screw the housing cover back onto the device.
7 Technical specifications 7.
Technical specifications 7.1 SCALANCE W786 technical specifications Interfaces Power • 48 VDC power supply (minimum permitted voltage 36 VDC, maximum permitted voltage 57 VDC) via supplied connector • RJ-45 jack Power over Ethernet 48 VDC (minimum permitted voltage 36 VDC, maximum permitted voltage 57 VDC) • 2 x 12 - 24 VDC power supplies (minimum permitted voltage 9.6 VDC, maximum permitted voltage 28.
Technical specifications 7.1 SCALANCE W786 technical specifications Permitted ambient conditions Operating temperature -40°C to +70°C Operation with 100 V to 240 V power supply -40°C to +60°C You should also note the temperature ranges specified in the approvals. Transportation/storage temperature -40°C to +85°C Degree of protection Tested to IP65 MTBF information (mean time between failure) MTBF 61 years Transmit power Table 7- 1 Transmit power in IEEE 802.11b mode (2.
Technical specifications 7.1 SCALANCE W786 technical specifications Table 7- 3 Transmit power in IEEE 802.11a/h mode (5 GHz) Data rate [Mbps] P0 [dBm] 6 17 9 17 12 17 18 17 24 17 36 16 48 15 54 13.5 Receiver sensitivity Table 7- 4 Receiver sensitivity in IEEE 802.11b mode (2.4 GHz) Data rate [Mbps] Pe [dBm] 1 -98 2 -94 5.5 -92 11 -90 Table 7- 5 Receiver sensitivity in IEEE 802.11g mode (2.
Technical specifications 7.2 Dimension drawing SCALANCE W786 Table 7- 6 7.2 Receiver sensitivity in IEEE 802.
Technical specifications 7.3 Permitted antennas 7.3 Permitted antennas Accessories for SCALANCE W-700 Note When you select an antenna, keep in mind the national approvals for your SCALANCE W7xx. Characteristics Type Frequency / GHz Antenna gain / dBi Impedance / Ω Order No. Omni ANT795-6MN 2.4 6 50 5 8 6GK57956MN00-0AA6 Omni ANT792-6MN 2.4 6 50 6GK57926MN00-0AA6 Omni ANT793-6MN 5 5 50 6GK57936MN00-0AA6 Patch ANT795-6DN 2.
Technical specifications 7.4 Radiation patterns diagrams of SCALANCE W786 internal antennas 7.
Technical specifications 7.
Technical specifications 7.
Technical specifications 7.
Certification 8.1 8 Approvals for SCALANCE W786 CE conformity The products SIMATIC NET SCALANCE W786-1PRO SIMATIC NET SCALANCE W786-2PRO SIMATIC NET SCALANCE W786-3PRO SIMATIC NET SCALANCE W786-2RR in the version put into circulation by Siemens AG meet the regulations of the following European directives: ● 99/5/EC Directive of the European Parliament and of the Council on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity.
Certification 8.
Certification 8.1 Approvals for SCALANCE W786 ATEX, FM and cULus approvals The products SCALANCE W786-1PRO SCALANCE W786-2PRO SCALANCE W786-3PRO SCALANCE W786-2RR have the following approvals ● EN 60079-15 : 2005 EN 60079-0 : 2006 II 3 G Ex nA II T4 KEMA 07 ATEX 0145 X Ta: -40 °C to +60 ℃ ● FM 3611 CL. 1, Div. 2 GP.A.B.C.D T4 CL. 1, Zone 2, GP.IIC. T4 Ta: -40 °C ... +70 ℃ 100 V ... 240 V Ta: -40 °C to +60 ℃ ● c-UL-us UL 60950-1, CSA C22.2 No. 60950-1 Ta: -40 °C ... 70℃ 100 V ...
Certification 8.1 Approvals for SCALANCE W786 SCALANCE W786-1PRO SCALANCE W786-2PRO SCALANCE W786-3PRO SCALANCE W786-2RR meet the stipulations of the following directives or standards: ● Directive 72/245/EC, last changed by directive 2006/28/EC Type approval number e1*72/245*2006/28*5311*00 E1: Number of approval 025311 Note The requirements are met only when the device is screwed to a mounting plate and a cover plate for the cabling.
Certification 8.1 Approvals for SCALANCE W786 Certification ID The following table shows the product names and the corresponding certification ID: Type Number and type of Ethernet ports Number of Number of R-SMA internal antennas sockets for external antennas Certification ID Order no. Order no.
Certification 8.
Certification 8.1 Approvals for SCALANCE W786 FCC approval This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IEEE802.11b or g operation of this product in the USA is firmware-limited to channels 1 through11.
Certification 8.1 Approvals for SCALANCE W786 To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden.
Certification 8.1 Approvals for SCALANCE W786 NCC Warning Statement (Taiwan) Article 12 Without permission, any company, firm or user shall not alter the frequency, increase the power, or change the characteristics and functions of the original design of the certified lower power frequency electric machinery.
Certification 8.
Certification 8.
Certification 8.1 Approvals for SCALANCE W786 Note The specified approvals apply only when the corresponding mark is printed on the product.
Certification 8.2 National approvals 8.2 National approvals National approvals The following table lists the countries in which the SCALANCE W700 product is approved. The diamond symbol (♦) identifies all countries for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: Http://www.siemens.com/funkzulassungen Column Meaning Country Country Mode IEEE 802.
Certification 8.
Certification 8.
Certification 8.
Certification 8.
Certification 8.
Certification 8.
Certification 8.
Certification 8.
Certification 8.
Certification 8.
Certification 8.
Certification 8.2 National approvals Country Mode CH Vietnam 11b 11g 11g Turbo 1 13 2412 2472 100 mW Indoor + outdoor 11a 5180 5240 200 mW Indoor only TPC 36 48 52 64 5260 5320 200 mW Indoor + outdoor DFS+TPC 11h MHz PWR (EIRP) Use The following notice applies only to the SCALANCE W786-2HPW: Note Before commissioning the SCALANCE W786-2HPW, check that the Hipath Wireless Controller required for operation is also approved in the country of use.
Certification 8.