Technical data

Communication
9.4 Communication via PROFINET IO
Function Manual
Function Manual, 06/2012, 6SL3097-4AB10-0BP4
667
Device selection in HW Config
Hardware catalog:
The drive unit from the appropriate unit family entry in the hardware catalog must be
configured. For the RT class IRT, these are all entries with the end identification ...PN-V2.2.
GSD:
The names of GSD files for devices which contain IRT end in …PN-V2.2.
9.4.4 Selection of the PROFINET variant
SINAMICS S110 supports the PROFINET variant:
PROFINET version 2.2 (RT class IRT)
The PROFINET variant required is stored in a separate UFW file for each variant. The
pointer file optboard.txt contains the names of the UFW files to be loaded. The pointer file
refers to PROFINET V2.2 by default.
Table 9- 41 UFW file and selection in the pointer file
UFW file and folder on memory card Functionality Pointer file content
/SIEMENS/SINAMICS/CODE/CB/
CBE20_1.UFW
PROFINET V2.2 CBE20=1
Identification of firmware version:
The OMI diagnostic channel, parameter r8858 can be read to identify which firmware version
of PROFINET interface is currently loaded.
9.4.5 PROFINET GSD
For integration into a PROFINET network, SINAMICS S110 supports two different
PROFINET GSD versions (device master file):
PROFINET GSD for compact modules
PROFINET GSD with subslot configuring
PROFINET GSD for compact modules
With the PROFINET GSD for compact modules, you can precisely configure a complete
module which corresponds to a drive object. Each of these modules involves two subslots:
The Parameter Access Point (PAP) and a PZD telegram for transferring process data. You
can identify the PROFINET GSD for compact modules by the following structure of the file
name:
GSDML-V2.25-Siemens-Sinamics_S110-20100803.xml (example)