Technical data
Communication   
9.3 Communication via PROFIBUS DP 
  Function Manual 
650  Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
Procedure 
1. In the overview for the PROFIBUS telegram, you can access the telegram portions of the 
drive objects, here SERVO_01. Select the telegram type "Free telegram configuration 
with BICO" for the configuration. 
2. Enter the telegram lengths for the input data and output data according to the settings in 
HW Config. For slave-to-slave communication links, the input data consists of the 
telegram portion of the master and the slave-to-slave communication data. 
3. Then, in the telegram selection, set the telegram portion to the "Standard telegram" (in 
the example: Standard telegram 2), which results in a split display of the telegram types 
(standard telegram + telegram extension). The telegram extension represents the 
telegram portion of slave-to-slave communication. 
Figure 9-36  Display of the telegram extension 
By selecting the item "Communication → PROFIBUS" for the drive object "SERVO_01" in the 
project navigator, you get the structure of the PROFIBUS telegram in the receive and send 
direction. 
The telegram extension from PZD5 is the portion for slave-to-slave communication. 