Technical data
  Communication 
  9.3 Communication via PROFIBUS DP 
Function Manual 
Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
629 
Device master file 
A device master file provides a full and clear description of the features of a PROFIBUS 
slave. 
The GSD files can be found at the following locations: 
●  On the CD for the STARTER commissioning tool 
Order no. 6SL3072-0AA00-0AGx 
Figure 9-21  Hardware catalog of the generic station description file with slave-to-slave 
communication functionality 
The "SINAMICS S110 CU305 V4.3" GSD file contains standard telegrams, free telegrams 
and slave-to-slave telegrams for configuring slave-to-slave communication. The user must 
take these telegram parts and an axis separator after each drive object (DO) to compose a 
telegram for the drive unit. 
Processing a GSD file in HW Config is covered in the SIMATIC documentation. 