Technical data
Commissioning with PROFIBUS   
3.6 Initial commissioning using servo AC DRIVE with BOP20 as an example 
  Function Manual 
60  Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
3.6  Initial commissioning using servo AC DRIVE with BOP20 as an 
example
The example provided in this section explains all the configuration and parameter settings 
that are required for first commissioning. Commissioning is performed using the BOP20. 
Commissioning requirement 
●  The check list for commissioning (Table 1-1 or 1-2 from Section 1.1) has been filled out 
and the points complied with. 
3.6.1  Task 
1. Commission a drive unit (operating mode servo, closed-loop speed control) with the 
following components: 
Table 3- 6  Component overview 
Designation  Component  Order number 
Closed-loop control 
Control Unit  Control Unit 305 DP  6SL3040-0JA00-0AA0 
Operator Panel  Basic Operator Panel 20 
(BOP20) 
6SL3055-0AA00-4BAx 
Drive 
Power Module  Power Module 340  6SL3210-xxxx-xxxx 
Motor  Synchronous motor with DRIVE-
CLiQ interface 
1FK7061-7AF7x-xAxx 
Motor encoder via DRIVE-CLiQ  Incremental encoder sin/cos 
C/D 
1 Vpp 2048 p/r 
1FK7xxx-xxxxx-xAxx 
2. Commissioning is performed using the BOP20. 
3. The function keys of the Basic Operator Panel (BOP) should be parameterized so that the 
ON/OFF signal and the speed setpoints are entered using these keys. 